Performance of a Low Activity Beta-Sensitive SR{sup 90} Water Monitor for Fukushima
Conference
·
OSTI ID:22531339
- Canberra Industries Inc. (United States)
There are large volumes of contaminated water from the stabilization efforts at the damaged Fukushima Nuclear Power Plants. This water is being processed to remove radioactivity for eventual release to the environment. An on-line continuously operating system to confirm that the clean-up system is working properly, and to provide prompt feedback of the results is required by the system operator. While gamma emitting nuclides allow for the straight forward approach of gamma spectroscopy to identify and quantify radioactivity in water, pure beta emitting nuclides such as Sr{sup 90} pose a challenging problem. The relatively short range of beta radiation in water requires optimization of the measurement geometry in terms of the source-detector distance and source-detector interface while retaining a background sensitivity low enough to meet the Minimum Detectable Concentration (MDC) of 10 Bq/kg in 180 minutes. This issue is complicated by the continuum nature of the beta spectrum which does not allow for simple nuclide identification. The use of the Monte-Carlo code MCNP to estimate system performance before prototyping vastly increases the success of the end product. Various parameters such as detector size and thickness, water chamber size, water chamber construction materials were evaluated to help choose the optimum geometry. The final design was a system consisting of two large-area (16 x 35 cm) and thin (0.15 mm) plastic scintillators placed very close to a sealed a water chamber. The size of the chamber was optimized to obtain the maximum efficiency for the nuclide being measured (Sr/Y{sup 90}) but to minimize the efficiency for possible interferences (Ru/Rh{sup 106}, Cs{sup 137}). A thin carbon fiber window was selected with adequate material and thickness to contain the water under pressure, but also thin enough (0.5 mm) to allow enough beta radiation to pass through to the active detector volume. The entire measurement geometry is then housed in a thick lead shield to reduce contributions from external sources to an acceptable level. Data acquisition is accomplished through customized application-specific software that allows for long counting times to attain a low MDC, but also simultaneously provides alarms on short averaging times to achieve a fast response to sudden changes in activity concentration. Multiple monitors are then linked to supervisory software where real time data and alarms are available for analysis in remote locations. The system also allows for remote operation of the unit; check sources, background checks, systems settings and more may be accessed remotely. Testing of the production devices has shown that we can achieve the 10 Bk/kg MDC requirement for Sr{sup 90} in equilibrium with Y{sup 90} with a count time of approximately 20 minutes. (authors)
- Research Organization:
- Institute of Electrical and Electronics Engineers - IEEE, 3 Park Avenue, 17th Floor, New York, N.Y. 10016-5997 (United States)
- OSTI ID:
- 22531339
- Report Number(s):
- ANIMMA--2015-IO-291
- Country of Publication:
- United States
- Language:
- English
Similar Records
Liquid effluent beta monitor
An ISPA camera for beta radiography
A SYSTEM FOR THE SIMULTANEOUS DETECTION OF TWENTY POSITRON-EMITTING SOURCES
Conference
·
Mon Jan 31 23:00:00 EST 1977
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:7213110
An ISPA camera for beta radiography
Journal Article
·
Tue Oct 01 00:00:00 EDT 1996
· IEEE Transactions on Nuclear Science
·
OSTI ID:413367
A SYSTEM FOR THE SIMULTANEOUS DETECTION OF TWENTY POSITRON-EMITTING SOURCES
Technical Report
·
Sun Jul 01 00:00:00 EDT 1962
·
OSTI ID:4816634
Related Subjects
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
BETA SPECTRA
CARBON FIBERS
CESIUM 137
CONCENTRATION RATIO
DATA ACQUISITION
FEEDBACK
FUKUSHIMA DAIICHI NUCLEAR POWER STATION
GAMMA SPECTROSCOPY
INTERFERENCE
M CODES
MONTE CARLO METHOD
PLASTIC SCINTILLATION DETECTORS
RADIATION MONITORS
RADIOACTIVITY
RHODIUM 106
SENSITIVITY
STABILIZATION
STRONTIUM 90
WATER
YTTRIUM 90
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
BETA SPECTRA
CARBON FIBERS
CESIUM 137
CONCENTRATION RATIO
DATA ACQUISITION
FEEDBACK
FUKUSHIMA DAIICHI NUCLEAR POWER STATION
GAMMA SPECTROSCOPY
INTERFERENCE
M CODES
MONTE CARLO METHOD
PLASTIC SCINTILLATION DETECTORS
RADIATION MONITORS
RADIOACTIVITY
RHODIUM 106
SENSITIVITY
STABILIZATION
STRONTIUM 90
WATER
YTTRIUM 90