Evaluation of the fate and pathological response in the lung and pleura of brake dust alone and in combination with added chrysotile compared to crocidolite asbestos following short-term inhalation exposure
Journal Article
·
· Toxicology and Applied Pharmacology
- Rogers Imaging, Needham, MA (United States)
- Fraunhofer Institute for Toxicology and Experimental Medicine, Hannover (Germany)
This study was designed to provide an understanding of the biokinetics and potential toxicology in the lung and pleura following inhalation of brake dust following short term exposure in rats. The deposition, translocation and pathological response of brake-dust derived from brake pads manufactured with chrysotile were evaluated in comparison to the amphibole, crocidolite asbestos. Rats were exposed by inhalation 6 h/day for 5 days to either brake-dust obtained by sanding of brake-drums manufactured with chrysotile, a mixture of chrysotile and the brake-dust or crocidolite asbestos. The chrysotile fibers were relatively biosoluble whereas the crocidolite asbestos fibers persisted through the life-time of the animal. This was reflected in the lung and the pleura where no significant pathological response was observed at any time point in the brake dust or chrysotile/brake dust exposure groups through 365 days post exposure. In contrast, crocidolite asbestos produced a rapid inflammatory response in the lung parenchyma and the pleura, inducing a significant increase in fibrotic response in both of these compartments. Crocidolite fibers were observed embedded in the diaphragm with activated mesothelial cells immediately after cessation of exposure. While no chrysotile fibers were found in the mediastinal lymph nodes, crocidolite fibers of up to 35 μm were observed. These results provide support that brake-dust derived from chrysotile containing brake drums would not initiate a pathological response in the lung or the pleural cavity following short term inhalation. - Highlights: • Evaluated brake dust w/wo added chrysotile in comparison to crocidolite asbestos. • Persistence, translocation, pathological response in the lung and pleural cavity. • Chrysotile cleared rapidly from the lung while the crocidolite asbestos persisted. • No significant pathology in lung or pleural cavity observed at any time point in the brake-dust groups. • Crocidolite quickly produced pathological response in the lung and pleural cavity.
- OSTI ID:
- 22465696
- Journal Information:
- Toxicology and Applied Pharmacology, Journal Name: Toxicology and Applied Pharmacology Journal Issue: 1 Vol. 283; ISSN TXAPA9; ISSN 0041-008X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Evaluation of the deposition, translocation and pathological response of brake dust with and without added chrysotile in comparison to crocidolite asbestos following short-term inhalation: Interim results
Early response of the visceral pleura following asbestos exposure: an ultrastructural study
Increased production of plasminogen activator inhibitor in vitro by pleural leukocytes from rats intratracheally instilled with crocidolite asbestos
Journal Article
·
Tue Apr 01 00:00:00 EDT 2014
· Toxicology and Applied Pharmacology
·
OSTI ID:22439687
Early response of the visceral pleura following asbestos exposure: an ultrastructural study
Journal Article
·
Mon Dec 31 23:00:00 EST 1984
· J. Toxicol. Environ. Health; (United States)
·
OSTI ID:6430368
Increased production of plasminogen activator inhibitor in vitro by pleural leukocytes from rats intratracheally instilled with crocidolite asbestos
Journal Article
·
Thu Aug 01 00:00:00 EDT 1991
· Environmental Research; (United States)
·
OSTI ID:6024398