Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $$\times$$ 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.
- Research Organization:
- Oak Ridge Y-12 Plant (Y-12), Oak Ridge, TN (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA)
- Grant/Contract Number:
- NA0003180
- OSTI ID:
- 2228847
- Journal Information:
- Journal of Nondestructive Evaluation, Journal Name: Journal of Nondestructive Evaluation Journal Issue: 4 Vol. 42; ISSN 0195-9298
- Publisher:
- Springer NatureCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Similar Records
Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel
System Response Characterization for a d–t Neutron Radiography System
Pulse shape measurements for neutron/gamma discrimination using the TOFPET2 ASIC
Journal Article
·
Wed Aug 07 00:00:00 EDT 2024
· Journal of Nondestructive Evaluation
·
OSTI ID:2441245
System Response Characterization for a d–t Neutron Radiography System
Technical Report
·
Thu Sep 01 00:00:00 EDT 2022
·
OSTI ID:1890040
Pulse shape measurements for neutron/gamma discrimination using the TOFPET2 ASIC
Journal Article
·
Thu Jul 06 00:00:00 EDT 2023
· Journal of Instrumentation
·
OSTI ID:2311646