Title: Importance of a Patient Dosimetry and Clinical Follow-up Program in the Detection of Radiodermatitis After Long Percutaneous Coronary Interventions

Journal Article · · Cardiovascular and Interventional Radiology
 [1];  [2];  [3];  [1];  [4]
  1. Instituto de Investigacion Sanitaria Hospital Clinico San Carlos and Complutense University, Medical Physics Service and Radiology Department (Spain)
  2. Hospital Clinico San Carlos, Cardiovascular Institute (Spain)
  3. Hospital Ramon y Cajal, Dermatology Service (Spain)
  4. Instituto de Investigacion Sanitaria Hospital Clinico San Carlos and Complutense University, Radiotherapy Service and Radiology Department (Spain)

Complex percutaneous interventions often require high radiation doses likely to produce skin radiation injuries. We assessed the methodology used to select patients with potential skin injuries in cardiac procedures and in need of clinical follow-up. We evaluated peak skin dose and clinical follow-up in a case of radiodermatitis produced during a total occlusion recanalization. This prospective study followed CIRSE and ACC/AHA/SCAI recommendations for patient radiation dose management in interventional procedures carried out in a university hospital with a workload of 4200 interventional cardiac procedures per year. Patient dose reports were automatically transferred to a central database. Patients exceeding trigger levels for air kerma area product (500 Gy cm{sup 2}) and cumulative skin dose (5 Gy) were counseled and underwent follow-up for early detection of skin injuries, with dermatologic support. The Ethical Committee and the Quality Assurance and Radiation Safety Committee approved the program. During 2010, a total of 13 patients (3.0/1,000 that year) received dose values exceeding trigger levels in the cardiovascular institute. Only one patient, who had undergone two consecutive procedures resulting in 970 Gy cm{sup 2} and 13.0 Gy as cumulative skin dose, showed signs of serious radiodermatitis that resolved in 3.7 months. The remaining patients did not manifest skin lesions during follow-up, and whenever patient examination was not feasible as part of the follow-up, neither patients nor families reported any skin injuries. Peak skin dose calculation and close clinical follow-up were feasible and appropriate, with a moderate additional workload for the staff and satisfaction for the patient.

OSTI ID:
22156388
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 36, Issue 2; Other Information: Copyright (c) 2013 Springer Science+Business Media New York and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); Article Copyright (c) 2012 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Radiation-induced skin cancer and radiodermatitis of the head and neck
Journal Article · Sun Feb 01 00:00:00 EST 1987 · Cancer (Philadelphia); (United States) · OSTI ID:22156388

Patient radiation dose audits for fluoroscopically guided interventional procedures
Journal Article · Tue Mar 15 00:00:00 EDT 2011 · Medical Physics · OSTI ID:22156388

Radiation-Induced Skin Injuries to Patients: What the Interventional Radiologist Needs to Know
Journal Article · Tue Aug 15 00:00:00 EDT 2017 · Cardiovascular and Interventional Radiology · OSTI ID:22156388