Title: Volumetric Modulation Arc Radiotherapy With Flattening Filter-Free Beams Compared With Static Gantry IMRT and 3D Conformal Radiotherapy for Advanced Esophageal Cancer: A Feasibility Study

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1]; ; ; ; ; ;  [2]; ;  [1];  [3]; ;  [1]
  1. Oncology Institute of Southern Switzerland, Medical Physics Unit, Bellinzona (Switzerland)
  2. Tata Memorial Hospital, Mumbai (India)
  3. Department of Radiation Oncology, Istituto Clinico Humanitas, Milano-Rozzano (Italy)

Purpose: A feasibility study was performed to evaluate RapidArc (RA), and the potential benefit of flattening filter-free beams, on advanced esophageal cancer against intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT). Methods and Materials: The plans for 3D-CRT and IMRT with three to seven and five to seven fixed beams were compared against double-modulated arcs with avoidance sectors to spare the lungs for 10 patients. All plans were optimized for 6-MV photon beams. The RA plans were studied for conventional and flattening filter-free (FFF) beams. The objectives for the planning target volume were the volume receiving {>=}95% or at most 107% of the prescribed dose of <1% with a dose prescription of 59.4 Gy. For the organs at risk, the lung volume (minus the planning target volume) receiving {>=}5 Gy was <60%, that receiving 20 Gy was <20%-30%, and the mean lung dose was <15.0 Gy. The heart volume receiving 45 Gy was <20%, volume receiving 30 Gy was <50%. The spinal dose received by 1% was <45 Gy. The technical delivery parameters for RA were assessed to compare the normal and FFF beam characteristics. Results: RA and IMRT provided equivalent coverage and homogeneity, slightly superior to 3D-CRT. The conformity index was 1.2 {+-} 0.1 for RA and IMRT and 1.5 {+-} 0.2 for 3D-CRT. The mean lung dose was 12.2 {+-} 4.5 for IMRT, 11.3 {+-} 4.6 for RA, and 10.8 {+-} 4.4 for RA with FFF beams, 18.2 {+-} 8.5 for 3D-CRT. The percentage of volume receiving {>=}20 Gy ranged from 23.6% {+-} 9.1% to 21.1% {+-} 9.7% for IMRT and RA (FFF beams) and 39.2% {+-} 17.0% for 3D-CRT. The heart and spine objectives were met by all techniques. The monitor units for IMRT and RA were 457 {+-} 139, 322 {+-} 20, and 387 {+-} 40, respectively. RA with FFF beams showed, compared with RA with normal beams, a {approx}20% increase in monitor units per Gray, a 90% increase in the average dose rate, and 20% reduction in beam on time (owing to different gantry speeds). Conclusion: RA demonstrated, compared with conventional IMRT, a similar target coverage and some better dose sparing to the organs at risk; the advantage against conventional 3D-CRT was more evident. RA with FFF beams resulted in minor improvements in plan quality but with the potential for additional useful reduction in the treatment time.

OSTI ID:
22149545
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 84, Issue 2; Other Information: Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English