Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy
- Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China)
- Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5K8 (Canada)
Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions: The proposed needle segmentation algorithm is accurate, robust, and suitable for 3D TRUS guided prostate transperineal therapy.
- OSTI ID:
- 22130603
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 4 Vol. 40; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Oblique needle segmentation and tracking for 3D TRUS guided prostate brachytherapy
Automated localization of implanted seeds in 3D TRUS images used for prostate brachytherapy
A compact mechatronic system for 3D ultrasound guided prostate interventions
Journal Article
·
Thu Sep 15 00:00:00 EDT 2005
· Medical Physics
·
OSTI ID:20726242
Automated localization of implanted seeds in 3D TRUS images used for prostate brachytherapy
Journal Article
·
Sat Jul 15 00:00:00 EDT 2006
· Medical Physics
·
OSTI ID:20853215
A compact mechatronic system for 3D ultrasound guided prostate interventions
Journal Article
·
Mon Feb 14 23:00:00 EST 2011
· Medical Physics
·
OSTI ID:22096893