A compact mechatronic system for 3D ultrasound guided prostate interventions
- Robarts Research Institute, 100 Perth Drive, London, Ontario N6A 5K8 (Canada) and Biomedical Engineering, University of Western Ontario, London, Ontario N6A 5B9 (Canada)
Purpose: Ultrasound imaging has improved the treatment of prostate cancer by producing increasingly higher quality images and influencing sophisticated targeting procedures for the insertion of radioactive seeds during brachytherapy. However, it is critical that the needles be placed accurately within the prostate to deliver the therapy to the planned location and avoid complications of damaging surrounding tissues. Methods: The authors have developed a compact mechatronic system, as well as an effective method for guiding and controlling the insertion of transperineal needles into the prostate. This system has been designed to allow guidance of a needle obliquely in 3D space into the prostate, thereby reducing pubic arch interference. The choice of needle trajectory and location in the prostate can be adjusted manually or with computer control. Results: To validate the system, a series of experiments were performed on phantoms. The 3D scan of the string phantom produced minimal geometric error, which was less than 0.4 mm. Needle guidance accuracy tests in agar prostate phantoms showed that the mean error of bead placement was less then 1.6 mm along parallel needle paths that were within 1.2 mm of the intended target and 1 deg. from the preplanned trajectory. At oblique angles of up to 15 deg. relative to the probe axis, beads were placed to within 3.0 mm along a trajectory that were within 2.0 mm of the target with an angular error less than 2 deg. Conclusions: By combining 3D TRUS imaging system to a needle tracking linkage, this system should improve the physician's ability to target and accurately guide a needle to selected targets without the need for the computer to directly manipulate and insert the needle. This would be beneficial as the physician has complete control of the system and can safely maneuver the needle guide around obstacles such as previously placed needles.
- OSTI ID:
- 22096893
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 2 Vol. 38; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Brachytherapy needle deflection evaluation and correction
Oblique needle segmentation and tracking for 3D TRUS guided prostate brachytherapy
Prostate Brachytherapy With Oblique Needles to Treat Large Glands and Overcome Pubic Arch Interference
Journal Article
·
Thu Mar 31 23:00:00 EST 2005
· Medical Physics
·
OSTI ID:20634667
Oblique needle segmentation and tracking for 3D TRUS guided prostate brachytherapy
Journal Article
·
Thu Sep 15 00:00:00 EDT 2005
· Medical Physics
·
OSTI ID:20726242
Prostate Brachytherapy With Oblique Needles to Treat Large Glands and Overcome Pubic Arch Interference
Journal Article
·
Wed Aug 01 00:00:00 EDT 2012
· International Journal of Radiation Oncology, Biology and Physics
·
OSTI ID:22149393