Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A needle guidance system for biopsy and therapy using two-dimensional ultrasound

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.2829871· OSTI ID:21036162
; ; ; ; ;  [1]
  1. Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8 (Canada) and Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada)
Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75{+-}0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists and inexperienced resident radiologists using free-hand US and the needle guidance system. Cylindrical polyvinyl alcohol cryogel lesions, colored blue, were embedded in chicken tissue. Radiologists identified the lesions, visible as hypoechoic masses in the US images, and performed biopsy using a 14-gauge needle. Procedure times were compared based on experience and the technique performed. Using a pair-wise t test, lower biopsy procedure times were observed when using the guidance system versus the free-hand technique (t=12.59, p<0.001). The authors believe that with this improved biopsy guidance they will be able to reduce the ''false negative'' rate of biopsies, especially in the hands of less experienced physicians.
OSTI ID:
21036162
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 2 Vol. 35; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy
Journal Article · Wed Nov 14 23:00:00 EST 2007 · Medical Physics · OSTI ID:21032846

Development and validation of a new guidance device for lateral approach stereotactic breast biopsy
Journal Article · Mon Jun 15 00:00:00 EDT 2009 · Medical Physics · OSTI ID:22100530

Real-Time 3D Fluoroscopy-Guided Large Core Needle Biopsy of Renal Masses: A Critical Early Evaluation According to the IDEAL Recommendations
Journal Article · Fri Jun 15 00:00:00 EDT 2012 · Cardiovascular and Interventional Radiology · OSTI ID:21608520