BrachyView, A novel inbody imaging system for HDR prostate brachytherapy: Design and Monte Carlo feasibility study
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)
- Faculty of Engineering and Information Technology, University of Technology, Sydney, NSW 2007 (Australia)
- Institute of Experimental and Applied Physics (IEAP), Czech Technical University in Prague (CTU) (Czech Republic)
- St. George Hospital Cancer Care Centre, Gray Street, Kogarah, NSW 2217 (Australia)
Purpose: High dose rate (HDR) brachytherapy is a form of radiation therapy for treating prostate cancer whereby a high activity radiation source is moved between predefined positions inside applicators inserted within the treatment volume. Accurate positioning of the source is essential in delivering the desired dose to the target area while avoiding radiation injury to the surrounding tissue. In this paper, HDR BrachyView, a novel inbody dosimetric imaging system for real time monitoring and verification of the radioactive seed position in HDR prostate brachytherapy treatment is introduced. The current prototype consists of a 15 Multiplication-Sign 60 mm{sup 2} silicon pixel detector with a multipinhole tungsten collimator placed 6.5 mm above the detector. Seven identical pinholes allow full imaging coverage of the entire treatment volume. The combined pinhole and pixel sensor arrangement is geometrically designed to be able to resolve the three-dimensional location of the source. The probe may be rotated to keep the whole prostate within the transverse plane. The purpose of this paper is to demonstrate the efficacy of the design through computer simulation, and to estimate the accuracy in resolving the source position (in detector plane and in 3D space) as part of the feasibility study for the BrachyView project.Methods: Monte Carlo simulations were performed using the GEANT4 radiation transport model, with a {sup 192}Ir source placed in different locations within a prostate phantom. A geometrically accurate model of the detector and collimator were constructed. Simulations were conducted with a single pinhole to evaluate the pinhole design and the signal to background ratio obtained. Second, a pair of adjacent pinholes were simulated to evaluate the error in calculated source location.Results: Simulation results show that accurate determination of the true source position is easily obtainable within the typical one second source dwell time. The maximum error in the estimated projection position was found to be 0.95 mm in the imaging (detector) plane, resulting in a maximum source positioning estimation error of 1.48 mm.Conclusions: HDR BrachyView is a feasible design for real-time source tracking in HDR prostate brachytherapy. It is capable of resolving the source position within a subsecond dwell time. In combination with anatomical information obtained from transrectal ultrasound imaging, HDR BrachyView adds a significant quality assurance capability to HDR brachytherapy treatment systems.
- OSTI ID:
- 22121617
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 7 Vol. 40; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Source position verification and dosimetry in HDR brachytherapy using an EPID
BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation
BrachyView: Proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy
Journal Article
·
Thu Nov 14 23:00:00 EST 2013
· Medical Physics
·
OSTI ID:22220248
BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation
Journal Article
·
Mon Dec 14 23:00:00 EST 2015
· Medical Physics
·
OSTI ID:22482437
BrachyView: Proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy
Journal Article
·
Mon Apr 15 00:00:00 EDT 2013
· Medical Physics
·
OSTI ID:22130576