Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.3263618· OSTI ID:22102185
; ; ;  [1]
  1. Department of Radiology and Department of Radiation and Cellular Oncology, University of Chicago, Chicago, Illinois 60637 (United States)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image of the patient is needed for image-guidance procedures. The authors previously developed an algorithm for image reconstruction from nontruncated data of an object that is completely within the reverse helix. The purpose of this work is to develop an image reconstruction approach for reverse helical CBCT of a long object that extends out of the reverse helix and therefore constitutes data truncation. Methods: The proposed approach comprises of two reconstruction steps. In the first step, a chord-based backprojection-filtration (BPF) algorithm reconstructs a volumetric image of an object from the original cone-beam data. Because there exists a chordless region in the middle of the reverse helix, the image obtained in the first step contains an unreconstructed central-gap region. In the second step, the gap region is reconstructed by use of a Pack-Noo-formula-based filteredbackprojection (FBP) algorithm from the modified cone-beam data obtained by subtracting from the original cone-beam data the reprojection of the image reconstructed in the first step. Results: The authors have performed numerical studies to validate the proposed approach in image reconstruction from reverse helical cone-beam data. The results confirm that the proposed approach can reconstruct accurate images of a long object without suffering from data-truncation artifacts or cone-angle artifacts. Conclusions: They developed and validated a BPF-FBP tandem algorithm to reconstruct images of a long object from reverse helical cone-beam data. The chord-based BPF algorithm was utilized for converting the long-object problem into a short-object problem. The proposed approach is applicable to other scanning configurations such as reduced circular sinusoidal trajectories.

OSTI ID:
22102185
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 1 Vol. 37; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

Exact BPF and FBP algorithms for nonstandard saddle curves
Journal Article · Mon Nov 14 23:00:00 EST 2005 · Medical Physics · OSTI ID:20726891

Region-of-interest image reconstruction in circular cone-beam microCT
Journal Article · Fri Dec 14 23:00:00 EST 2007 · Medical Physics · OSTI ID:21032894

PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch
Journal Article · Mon Aug 15 00:00:00 EDT 2005 · Medical Physics · OSTI ID:20726276