Region-of-interest image reconstruction in circular cone-beam microCT

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.2804924· OSTI ID:21032894
; ; ; ; ;  [1]
  1. Department of Radiology and Department of Radiation and Cellular Oncology, University of Chicago, Chicago, Illinois 60637 (United States)

Cone-beam microcomputed tomography (microCT) is one of the most popular choices for small animal imaging which is becoming an important tool for studying animal models with transplanted diseases. Region-of-interest (ROI) imaging techniques in CT, which can reconstruct an ROI image from the projection data set of the ROI, can be used not only for reducing imaging-radiation exposure to the subject and scatters to the detector but also for potentially increasing spatial resolution of the reconstructed images. Increasing spatial resolution in microCT images can facilitate improved accuracy in many assessment tasks. A method proposed previously for increasing CT image spatial resolution entails the exploitation of the geometric magnification in cone-beam CT. Due to finite detector size, however, this method can lead to data truncation for a large geometric magnification. The Feldkamp-Davis-Kress (FDK) algorithm yields images with artifacts when truncated data are used, whereas the recently developed backprojection filtration (BPF) algorithm is capable of reconstructing ROI images without truncation artifacts from truncated cone-beam data. We apply the BPF algorithm to reconstructing ROI images from truncated data of three different objects acquired by our circular cone-beam microCT system. Reconstructed images by use of the FDK and BPF algorithms from both truncated and nontruncated cone-beam data are compared. The results of the experimental studies demonstrate that, from certain truncated data, the BPF algorithm can reconstruct ROI images with quality comparable to that reconstructed from nontruncated data. In contrast, the FDK algorithm yields ROI images with truncation artifacts. Therefore, an implication of the studies is that, when truncated data are acquired with a configuration of a large geometric magnification, the BPF algorithm can be used for effective enhancement of the spatial resolution of a ROI image.

OSTI ID:
21032894
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 12 Vol. 34; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

An FDK-like cone-beam SPECT reconstruction algorithm fornon-uniform attenuated projections acquired using a circulartrajectory
Journal Article · Thu May 05 00:00:00 EDT 2005 · Physics in Medicine and Biology · OSTI ID:860352

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT
Journal Article · Thu Jan 14 23:00:00 EST 2010 · Medical Physics · OSTI ID:22102185

Model-based reconstruction for enhanced x-ray CT of dense tri-structural isotropic particles
Conference · Mon Jan 31 23:00:00 EST 2022 · OSTI ID:1885390