Can volumetric modulated arc therapy with flattening filter free beams play a role in stereotactic body radiotherapy for liver lesions? A volume-based analysis

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.3679858· OSTI ID:22098745

Purpose: To compare volumetric modulated arc therapy with flattening filter free (FFF) and flattening filter (FF) beams in patients with hepatic metastases subject to hypofractionated radiotherapy (RT). Methods: A planning study on 13 virtual lesions of increasing volume was performed. Two single arc plans were optimized with the RapidArc technique using either FFF or FF beams. A second planning study was performed on ten patients treated for liver metastases to validate conclusions. In all cases, a dose of 75 Gy in 3 fractions was prescribed to the planning target volume (PTV) and plans were evaluated in terms of coverage, homogeneity, conformity, mean dose to healthy liver and to healthy tissue. For each parameter, results were expressed in relative terms as the percentage ratio between FFF and FF data. Results: In terms of PTV coverage, conformity index favored FFF for targets of intermediate size while FF resulted more suitable for small (<100 cm{sup 3}) and large (>300 cm{sup 3}) targets. Plans optimized with FFF beams resulted in increased sparing of healthy tissue in {approx_equal}85% of cases. Despite the qualitative results, no statistically significant differences were found between FFF and FF results. Plans optimized with un-flattened beams resulted in higher average MU/Gy than plans with FF beams. A remarkable and significant difference was observed in the beam-on time (BOT) needed to deliver plans. The BOT for FF plans was 8.2 {+-} 1.0 min; for FFF plans BOT was 2.2 {+-} 0.2 min. Conclusions: RapidArc plans optimized using FFF were dosimetrically equivalent to those optimized using FF beams, showing the feasibility of SBRT treatments with FFF beams. Some improvement in healthy tissue sparing was observed when using the FFF modality due to the different beam's profile. The main advantage was a considerable reduction of beam-on time, relevant for SBRT techniques.

OSTI ID:
22098745
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 2 Vol. 39; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

Identification of the suitable leaf margin for liver stereotactic body radiotherapy with flattening filter-free beams
Journal Article · Thu Dec 14 23:00:00 EST 2017 · Medical Dosimetry · OSTI ID:22824167

SU-E-T-538: Lung SBRT Dosimetric Comparison of 3D Conformal and RapidArc Planning
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22496254

Fast Arc Delivery for Stereotactic Body Radiotherapy of Vertebral and Lung Tumors
Journal Article · Tue May 01 00:00:00 EDT 2012 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22056359