Influence of photon energy spectra from brachytherapy sources on Monte Carlo simulations of kerma and dose rates in water and air
- Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States)
Purpose: For a given radionuclide, there are several photon spectrum choices available to dosimetry investigators for simulating the radiation emissions from brachytherapy sources. This study examines the dosimetric influence of selecting the spectra for {sup 192}Ir, {sup 125}I, and {sup 103}Pd on the final estimations of kerma and dose. Methods: For {sup 192}Ir, {sup 125}I, and {sup 103}Pd, the authors considered from two to five published spectra. Spherical sources approximating common brachytherapy sources were assessed. Kerma and dose results from GEANT4, MCNP5, and PENELOPE-2008 were compared for water and air. The dosimetric influence of {sup 192}Ir, {sup 125}I, and {sup 103}Pd spectral choice was determined. Results: For the spectra considered, there were no statistically significant differences between kerma or dose results based on Monte Carlo code choice when using the same spectrum. Water-kerma differences of about 2%, 2%, and 0.7% were observed due to spectrum choice for {sup 192}Ir, {sup 125}I, and {sup 103}Pd, respectively (independent of radial distance), when accounting for photon yield per Bq. Similar differences were observed for air-kerma rate. However, their ratio (as used in the dose-rate constant) did not significantly change when the various photon spectra were selected because the differences compensated each other when dividing dose rate by air-kerma strength. Conclusions: Given the standardization of radionuclide data available from the National Nuclear Data Center (NNDC) and the rigorous infrastructure for performing and maintaining the data set evaluations, NNDC spectra are suggested for brachytherapy simulations in medical physics applications.
- OSTI ID:
- 22098504
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 2 Vol. 37; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
On determining dose rate constants spectroscopically
Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for {sup 125}I and {sup 103}Pd brachytherapy sources relative to {sup 60}Co
Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for {sup 137}Cs, {sup 125}I, {sup 192}Ir, {sup 103}Pd, and {sup 169}Yb sources
Journal Article
·
Mon Jan 14 23:00:00 EST 2013
· Medical Physics
·
OSTI ID:22099171
Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for {sup 125}I and {sup 103}Pd brachytherapy sources relative to {sup 60}Co
Journal Article
·
Sun Dec 14 23:00:00 EST 2014
· Medical Physics
·
OSTI ID:22403186
Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for {sup 137}Cs, {sup 125}I, {sup 192}Ir, {sup 103}Pd, and {sup 169}Yb sources
Journal Article
·
Thu Jun 15 00:00:00 EDT 2006
· Medical Physics
·
OSTI ID:20853186