Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Influence of intensity loss in the cavity of a folded Fabry-Perot interferometer on interferometric signals

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.3596451· OSTI ID:22062340
 [1];  [2];  [3]
  1. Department of Electro-Optical Engineering, National Formosa University, 64 Wunhua Road, Huwei, Yunlin, Taiwan (China)
  2. Department of Mechanical Engineering, National Central University, 300 Jhongda Road, Jhongli, Taoyuan, Taiwan (China)
  3. Institute of Mechanical Engineering, National Yunlin University of Science and Technology, 123 University Road, Section 3, Douliou, Yunlin, Taiwan (China)

Fabry-Perot interferometer is often used for the micro-displacement, because of its common optical path structure being insensitive to the environmental disturbances. Recently, the folded Fabry-Perot interferometer has been investigated for displacement measurements in large ranges. The advantages of a folded Fabry-Perot interferometer are insensitive to the tilt angle and higher optical resolution. But the design of the optical cavity has become more and more complicated. For this reason, the intensity loss in the cavity will be an important parameter for the distribution of the interferometric intensity. To obtain a more accurate result of such interferometer utilized for displacement measurements, the intensity loss of the cavity in the fabricated folded Fabry-Perot interferometer and the modified equation of the folded Fabry-Perot interferometer will be described. According to the theoretical and experimental results, the presented model is available for the analysis of displacement measurements by a folded Fabry-Perot interferometer.

OSTI ID:
22062340
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 6 Vol. 82; ISSN 0034-6748; ISSN RSINAK
Country of Publication:
United States
Language:
English

Similar Records

Fabry-Perot interferometer utilized for displacement measurement in a large measuring range
Journal Article · Wed Sep 15 00:00:00 EDT 2010 · Review of Scientific Instruments · OSTI ID:22055722

High-temperature fiber-optic Fabry-Perot interferometric sensors
Journal Article · Fri May 15 00:00:00 EDT 2015 · Review of Scientific Instruments · OSTI ID:22392510

Effect of stoke's displacement of absorption and emission bands on optical bistability in a fabry-perot interferometer
Journal Article · Fri Feb 28 23:00:00 EST 1986 · J. Appl. Spectrosc. (Engl. Transl.); (United States) · OSTI ID:5465878