Life-testing oxide confined VCSELs: Too good to last?
The use of native oxides (selective oxidation) in vertical cavity surface emitting lasers has produced dramatic improvements in these laser diodes but has also been suspected of causing poor reliability because of incidental reports of short lifetimes and physical considerations. Here we discuss the results of thousands of hours life-tests for oxide confined and implant confined devices at current densities from 1 to 12 kA/cm{sup 2}. There was a single infant mortality failure from a sample of 14 oxide confined lasers with the remainder showing relatively stable operation. The failed device is analyzed in terms of light current characteristics and near-field electroluminescence images, and potential screening criteria are proposed.
- Research Organization:
- Sandia National Labs., Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 220598
- Report Number(s):
- SAND--96-0696C; CONF-960163--8; ON: DE96006989
- Country of Publication:
- United States
- Language:
- English
Similar Records
Low threshold current implanted-planar buried-heterostructure graded-index separate confinement heterostructure laser in GaAs/AlGaAs