Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Renal Artery Embolization Combined With Radiofrequency Ablation in a Porcine Kidney Model: Effect of Small and Narrowly Calibrated Microparticles as Embolization Material on Coagulation Diameter, Volume, and Shape

Journal Article · · Cardiovascular and Interventional Radiology
 [1];  [2];  [3]; ;  [1]; ; ;  [3]; ;  [4];  [2];  [5]; ;  [1]
  1. University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)
  2. German Cancer Research Center, Division of Medical and Biological Informatics (Germany)
  3. University Hospital Heidelberg, Department of General, Abdominal and Transplantation Surgery (Germany)
  4. University Hospital Heidelberg, Department of General Pathology (Germany)
  5. Klinikum Stuttgart, Department of Diagnostic and Interventional Radiology (Germany)

The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume{sub s}egmented, and volume{sub c}alculated were determined to describe the size of the RFAs. To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 {+-} 3.6 vs. 17.2 {+-} 1.8 mm; p < 0.001) and width (20.1 {+-} 2.9 vs. 12.6 {+-} 3.7 mm; p < 0.001); significantly larger volume{sub s}egmented (8.6 {+-} 3.2 vs. 3.0 {+-} 0.7 ml; p < 0.001) and volume{sub c}alculated (8.4 {+-} 3.0 ml vs. 3.3 {+-} 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 {+-} 0.10 vs. 1.48 {+-} 0.44; p < 0.05), sphericity (1.55 {+-} 0.44 vs. 1.96 {+-} 0.43; p < 0.01), and eccentricity (0.84 {+-} 0.61 vs. 1.73 {+-} 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 {+-} 0.14 vs. 0.45 {+-} 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.

OSTI ID:
21608816
Journal Information:
Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 1 Vol. 34; ISSN 0174-1551; ISSN CAIRDG
Country of Publication:
United States
Language:
English

Similar Records

Patients with Life-Threatening Arterial Renal Hemorrhage: CT Angiography and Catheter Angiography with Subsequent Superselective Embolization
Journal Article · Tue Jun 15 00:00:00 EDT 2010 · Cardiovascular and Interventional Radiology · OSTI ID:21428979

Looking for the Ideal Particle: An Experimental Embolization Study
Journal Article · Thu Apr 15 00:00:00 EDT 2010 · Cardiovascular and Interventional Radiology · OSTI ID:21429019

Radiofrequency Ablation in Combination with Embolization in Metachronous Recurrent Renal Cancer in Solitary Kidney after Contralateral Tumor Nephrectomy
Journal Article · Sun Jul 15 00:00:00 EDT 2007 · Cardiovascular and Interventional Radiology · OSTI ID:21090866