Syringe and Needle Size, Syringe Type, Vacuum Generation, and Needle Control in Aspiration Procedures
Journal Article
·
· Cardiovascular and Interventional Radiology
Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm{sup 2}), (4) operator difficulty during aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of -517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (-435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.
- OSTI ID:
- 21608706
- Journal Information:
- Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 3 Vol. 34; ISSN 0174-1551; ISSN CAIRDG
- Country of Publication:
- United States
- Language:
- English
Similar Records
Image-Directed Fine-needle Aspiration Biopsy of the Thyroid with Safety-engineered Devices
Capillary Versus Aspiration Biopsy: Effect of Needle Size and Length on the Cytopathological Specimen Quality
Guided percutaneous fine-needle aspiration biopsy of the liver
Journal Article
·
Sat Oct 15 00:00:00 EDT 2011
· Cardiovascular and Interventional Radiology
·
OSTI ID:21608596
Capillary Versus Aspiration Biopsy: Effect of Needle Size and Length on the Cytopathological Specimen Quality
Journal Article
·
Sun Sep 15 00:00:00 EDT 1996
· Cardiovascular and Interventional Radiology
·
OSTI ID:21080502
Guided percutaneous fine-needle aspiration biopsy of the liver
Journal Article
·
Tue Mar 31 23:00:00 EST 1981
· Cancer (Philadelphia); (United States)
·
OSTI ID:5392769