Capillary Versus Aspiration Biopsy: Effect of Needle Size and Length on the Cytopathological Specimen Quality
Journal Article
·
· Cardiovascular and Interventional Radiology
- Department of Radiology, Penn State University, P.O. Box 850, Hershey, PA 17033 (United States)
- Department of Pathology, Penn State University, P.O. Box 850, Hershey, PA 17033 (United States)
- Center for Biostatistics and Epidemiology, Penn State University, P.O. Box 850, Hershey, PA 17033 (United States)
Purpose: To test the value of the nonaspiration, or capillary, biopsy technique by experimental comparison with the conventional fine-needle aspiration technique using various needle gauges and lengths. Methods: On fresh hepatic and renal tissue from five autopsies, multiple biopsy specimens were taken with 20, 22, and 23-gauge Chiba needles of 5, 10, 15, and 20-cm length, using the aspiration technique and the capillary technique. The resultant specimens were graded on the basis of a grading scheme by a cytopathologist who was blinded to the biopsy technique. Results: The capillary technique obtained less background blood or clot which could obscure diagnostic tissue, although not significantly different from the aspiration technique (p= 0.2). However, for the amount of cellular material obtained, retention of appropriate architecture, and mean score, the capillary technique performed statistically worse than aspiration biopsy (p < 0.01). In addition, with decreasing needle caliber (increasing needle gauge) and increasing length, the capillary biopsy was inferior to the aspiration biopsy. Conclusion: The capillary biopsy technique is inferior to the aspiration technique according to our study. When the capillary technique is to be applied, preference should be given to larger caliber, shorter needles.
- OSTI ID:
- 21080502
- Journal Information:
- Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 5 Vol. 19; ISSN 0174-1551; ISSN CAIRDG
- Country of Publication:
- United States
- Language:
- English
Similar Records
Percutaneous CT-Guided Biopsy of the Lung: Comparison Between Aspiration and Automated Cutting Needles Using a Coaxial Technique
Guided percutaneous fine-needle aspiration biopsy of the liver
MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach
Journal Article
·
Sat Jul 15 00:00:00 EDT 2000
· Cardiovascular and Interventional Radiology
·
OSTI ID:21083629
Guided percutaneous fine-needle aspiration biopsy of the liver
Journal Article
·
Tue Mar 31 23:00:00 EST 1981
· Cancer (Philadelphia); (United States)
·
OSTI ID:5392769
MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach
Journal Article
·
Mon Feb 14 23:00:00 EST 2011
· Cardiovascular and Interventional Radiology
·
OSTI ID:21608832