Operational stability of a compact 600-W KrF laser

Journal Article · · Quantum Electronics (Woodbury, N.Y.)
; ; ;  [1]; ; ;  [2]
  1. State Research Center of Russian Federation 'Troitsk Institute for Innovation and Fusion Research', Troitsk, Moscow Region (Russian Federation)
  2. Lambda Physik GmbH, Gottingen (Germany)
The problem of the operational stability of a KrF laser with an average output power of at least 600 W was investigated. An experimental study was made of the dependences of the rms deviation {sigma} of the output energy on the charging voltage, on the pulse repetition rate, and on the operating time. The value of {sigma} varied from 1.2% to 6.0%, depending on the experimental conditions. For an average power of {approx} 600 W, the deviation {sigma} did not exceed 3.2%. (lasers and amplifiers)