skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Replacement of Mushroom Cage Gastrostomy Tube Using a Modified Technique to Allow Percutaneous Replacement with an Endoscopic Tube in Patients with Amyotrophic Lateral Sclerosis

Journal Article · · Cardiovascular and Interventional Radiology
 [1];  [2];  [3]
  1. King's College Hospital, Department of Radiology (United Kingdom)
  2. King's College Hospital, Department of Dietetics (United Kingdom)
  3. King's College Hospital, Department of Neurosciences (United Kingdom)

Radiologic inserted gastrostomy (RIG) is the preferred method in our institution for enteral feeding in amyotrophic lateral sclerosis (ALS). Skin-level primary-placed mushroom cage gastrostomy tubes become tight with weight gain. We describe a minimally invasive radiologic technique for replacing mushroom gastrostomy tubes with endoscopic mushroom cage tubes in ALS. All patients with ALS who underwent replacement of a RIG tube were included. Patients were selected for a modified replacement when the tube length of the primary placed RIG tube was insufficient to allow like-for-like replacement. Replacement was performed under local anesthetic and fluoroscopic guidance according to a preset technique, with modification of an endoscopic mushroom cage gastrostomy tube to allow percutaneous placement. Assessment of the success, safety, and durability of the modified technique was undertaken. Over a 60-month period, 104 primary placement mushroom cage tubes in ALS were performed. A total of 20 (19.2%) of 104 patients had a replacement tube positioned, 10 (9.6%) of 104 with the modified technique (male n = 4, female n = 6, mean age 65.5 years, range 48-85 years). All tubes were successfully replaced using this modified technique, with two minor complications (superficial wound infection and minor hemorrhage). The mean length of time of tube durability was 158.5 days (range 6-471 days), with all but one patient dying with a functional tube in place. We have devised a modification to allow percutaneous replacement of mushroom cage gastrostomy feeding tubes with minimal compromise to ALS patients. This technique allows tube replacement under local anesthetic, without the need for sedation, an important consideration in ALS.

OSTI ID:
21428981
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 33, Issue 3; Other Information: DOI: 10.1007/s00270-009-9763-8; Copyright (c) 2010 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Radiologic Percutaneous Gastrostomy in Nondistended Stomach: A Modified Approach
Journal Article · Fri Jul 15 00:00:00 EDT 2016 · Cardiovascular and Interventional Radiology · OSTI ID:21428981

CIRSE Standards of Practice Guidelines on Gastrostomy
Journal Article · Fri Jul 15 00:00:00 EDT 2016 · Cardiovascular and Interventional Radiology · OSTI ID:21428981

Percutaneous Gastrostomy in Patients Who Fail or Are Unsuitable for Endoscopic Gastrostomy
Journal Article · Sat Jul 15 00:00:00 EDT 2000 · Cardiovascular and Interventional Radiology · OSTI ID:21428981