Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Radiologic Percutaneous Gastrostomy in Nondistended Stomach: A Modified Approach

Journal Article · · Cardiovascular and Interventional Radiology
; ; ; ;  [1]
  1. IRCCS San Martino University Hospital, Department of Radiology and Interventional Radiology (Italy)
IntroductionGastrostomy tube placement for patients requiring long-term nutritional support may be performed using different techniques including endoscopic, surgical, and percutaneous radiologically guided methods. Radiologically inserted gastrostomy (RIG), typically performed when percutaneous endoscopic gastrostomy is not possible, requires proper gastric distension that is achieved by insufflating air through a nasogastric tube. We describe a simple technique to prevent air escape from the stomach during gastrostomy tube placement. To the best of our knowledge, this technique has not yet been described in the literature.Materials and MethodsFour patients with unsuccessful percutaneous endoscopic gastrostomy were referred for fluoroscopic-guided gastrostomy. One patient had a pyriform sinus tumor and three had an ischemic stroke causing dysphagia. Gastric distention was not achieved in the patients due to air escaping into the bowel during the standard RIG procedure. A modified approach using a balloon catheter inflated in the pylorus to avoid air passing into the duodenum permitted successful RIG.ResultsThe modified RIG procedure was successfully carried out in all cases without complications.DiscussionInadequate air distension of the stomach is an unusual event that causes a failure of gastrostomy tube placement and an increased risk of both major and minor complications. The use of a balloon catheter inflated in the first part of the duodenum prevents the air passage into the bowel allowing the correct positioning of the gastrostomy.
OSTI ID:
22642489
Journal Information:
Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 7 Vol. 39; ISSN 0174-1551; ISSN CAIRDG
Country of Publication:
United States
Language:
English

Similar Records

Gastrostomy Tube Placement Without Nasogastric Tube: A Retrospective Evaluation in 85 Patients
Journal Article · Fri Dec 14 23:00:00 EST 2012 · Cardiovascular and Interventional Radiology · OSTI ID:22066516

Fluoroscopy-Guided Pull-Through Gastrostomy
Journal Article · Mon Jan 14 23:00:00 EST 2008 · Cardiovascular and Interventional Radiology · OSTI ID:21090690

Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter
Journal Article · Wed Jun 15 00:00:00 EDT 2011 · Cardiovascular and Interventional Radiology · OSTI ID:21608688