Does Three-Dimensional External Beam Partial Breast Irradiation Spare Lung Tissue Compared With Standard Whole Breast Irradiation?

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1]; ;  [1]
  1. Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida (United States)

Purpose: To determine whether three-dimensional conformal partial breast irradiation (3D-PBI) spares lung tissue compared with whole breast irradiation (WBI) and to include the biologically equivalent dose (BED) to account for differences in fractionation. Methods and Materials: Radiotherapy treatment plans were devised for WBI and 3D-PBI for 25 consecutive patients randomized on the NSABP B-39/RTOG 0413 protocol at Mayo Clinic in Jacksonville, Florida. WBI plans were for 50 Gy in 25 fractions, and 3D-PBI plans were for 38.5 Gy in 10 fractions. Volume of ipsilateral lung receiving 2.5, 5, 10, and 20 Gy was recorded for each plan. The linear quadratic equation was used to calculate the corresponding dose delivered in 10 fractions and volume of ipsilateral lung receiving these doses was recorded for PBI plans. Ipsilateral mean lung dose was recorded for each plan and converted to BED. Results: There was a significant decrease in volume of lung receiving 20 Gy with PBI (median, 4.4% vs. 7.5%; p < 0.001), which remained after correction for fractionation (median, 5.6% vs. 7.5%; p = 0.02). Mean lung dose was lower for PBI (median, 3.46 Gy vs. 4.57 Gy; p = 0.005), although this difference lost significance after conversion to BED (median, 3.86 Gy{sub 3} vs 4.85 Gy{sub 3}, p = 0.07). PBI plans exposed more lung to 2.5 and 5 Gy. Conclusions: 3D-PBI exposes greater volumes of lung tissue to low doses of radiation and spares the amount of lung receiving higher doses when compared with WBI.

OSTI ID:
21281996
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Journal Name: International Journal of Radiation Oncology, Biology and Physics Journal Issue: 1 Vol. 75; ISSN IOBPD3; ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

Dosimetric comparison of partial and whole breast external beam irradiation in the treatment of early stage breast cancer
Journal Article · Fri Dec 14 23:00:00 EST 2007 · Medical Physics · OSTI ID:21032871

Preoperative Single Fraction Partial Breast Radiotherapy for Early-Stage Breast Cancer
Journal Article · Sat Dec 31 23:00:00 EST 2011 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22055911

Dosimetric comparison of two different three-dimensional conformal external beam accelerated partial breast irradiation techniques
Journal Article · Thu Jun 01 00:00:00 EDT 2006 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20793490