Controlled flow, split flame low NOx burner system performance on a tangentially fired boiler
Conference
·
OSTI ID:211740
- Wisconsin Electric Power Co., Milwaukee, WI (United States). Dept. of Fossil Operations
- Foster Wheeler Energy Corp., Clinton, NJ (United States). Combustion Systems Design and Development
Presented are the results from both short term optimization testing and long term emission monitoring obtained during the first time application of the controlled-flow, split-flame (CF/SF) low-NOx burner design, used on wall fired boilers, to a boiler having a tangential firing design. Goal of this demonstration was to achieve desired NOx emission reductions, and to develop a production model tangential low NOx (TLN) burner design based upon a prototype burner system installed in 1992. Installation of this burner system occurred without the modification of waterwalls, or addition of separated over fire air. During testing of the prototype TLN burner system, it was found that a combination of optimized burners along with vertical secondary air staging provided the desired emission reduction over the entire boiler load range. Data reported is from the operational testing of the production model tangential low NOx, CF/SF burner system, which was installed in 1994.
- OSTI ID:
- 211740
- Report Number(s):
- CONF-951010--; ISBN 0-7918-1486-6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Performance of a controlled flow/split flame low-NOx burner system on a tangentially fired boiler
Neural network boiler optimization of efficiency, emission, and reliability with TVA Kingston Unit 3 low NOx optimization test results
Field evaluation of a low-NOx firing system for tangentially coal-fired utility boilers. Final report, August 1981-March 1984
Technical Report
·
Sun Dec 31 23:00:00 EST 1995
·
OSTI ID:269428
Neural network boiler optimization of efficiency, emission, and reliability with TVA Kingston Unit 3 low NOx optimization test results
Book
·
Sat Dec 30 23:00:00 EST 1995
·
OSTI ID:405650
Field evaluation of a low-NOx firing system for tangentially coal-fired utility boilers. Final report, August 1981-March 1984
Technical Report
·
Wed May 01 00:00:00 EDT 1985
·
OSTI ID:5500398