Field evaluation of a low-NOx firing system for tangentially coal-fired utility boilers. Final report, August 1981-March 1984
Technical Report
·
OSTI ID:5500398
The report gives results of a full-scale utility demonstration of Combustion Engineering's Low-NOx Concentric Firing System (LNCFS), conducted at Utah Power and Light's 400-MWe Hunter No. 2 boiler. This program was implemented to investigate and evaluate the effectiveness of using concentric (offset) firing to reduce NOx emission levels from tangentially coal-fired utility boilers. The tests covered the period from August 1981 to March 1984 and included six short-term boiler characterization test series and four long-term (30-day) continuous emissions monitor (CEM) tests. A total of 384 characterization tests were conducted during the six test series, analyzing boiler performance and emissions as functions of excess air, load, fuel elevations in service, burner tilt, overfire air (OFA) flow, OFA tilt, offset angle, and fuel-air flow. Additionally, furnace wall corrosion was monitored, both short- (with corrosion coupons) and long-term (with wall-thickness measurements), by another contractor. Overall program results have shown NOx emissions levels of about 0.4 lb NOx per million Btu for the 30-day continuous monitoring periods and about 0.3 lb NOx per million Btu for the short-term optimization tests. These levels represent 33 and 50% reductions in NOx emissions levels, respectively, from baseline standard operating procedures.
- Research Organization:
- Combustion Engineering, Inc., Windsor, CT (USA)
- OSTI ID:
- 5500398
- Report Number(s):
- PB-85-201093/XAB
- Country of Publication:
- United States
- Language:
- English
Similar Records
180 MW demonstration of advanced tangentially-fired combustion techniques for the reduction of nitrogen oxide (NO sub x ) emissions from coal-fired boilers
Advanced In-Furnace NOx Control for Wall and Cyclone-Fired Boilers
180 MW demonstration of advanced tangentially-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. Technical progress report second quarter, 1991
Technical Report
·
Mon Dec 31 23:00:00 EST 1990
·
OSTI ID:5969340
Advanced In-Furnace NOx Control for Wall and Cyclone-Fired Boilers
Technical Report
·
Thu Dec 31 19:00:00 EST 2009
·
OSTI ID:1037870
180 MW demonstration of advanced tangentially-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. Technical progress report second quarter, 1991
Technical Report
·
Mon Dec 30 23:00:00 EST 1991
·
OSTI ID:10113983
Related Subjects
01 COAL, LIGNITE, AND PEAT
010800 -- Coal
Lignite
& Peat-- Waste Management
20 FOSSIL-FUELED POWER PLANTS
200202* -- Fossil-Fueled Power Plants-- Waste Management-- Noxious Gas & Particulate Emissions
500200 -- Environment
Atmospheric-- Chemicals Monitoring & Transport-- (-1989)
54 ENVIRONMENTAL SCIENCES
AIR POLLUTION ABATEMENT
BOILERS
CARBONACEOUS MATERIALS
CHALCOGENIDES
COAL
COMBUSTION PRODUCTS
ENERGY SOURCES
FIELD TESTS
FOSSIL FUELS
FOSSIL-FUEL POWER PLANTS
FUELS
INDUSTRIAL WASTES
MATERIALS
NITROGEN COMPOUNDS
NITROGEN OXIDES
OXIDES
OXYGEN COMPOUNDS
POLLUTION ABATEMENT
POWER PLANTS
SAMPLING
TESTING
THERMAL POWER PLANTS
WASTES
010800 -- Coal
Lignite
& Peat-- Waste Management
20 FOSSIL-FUELED POWER PLANTS
200202* -- Fossil-Fueled Power Plants-- Waste Management-- Noxious Gas & Particulate Emissions
500200 -- Environment
Atmospheric-- Chemicals Monitoring & Transport-- (-1989)
54 ENVIRONMENTAL SCIENCES
AIR POLLUTION ABATEMENT
BOILERS
CARBONACEOUS MATERIALS
CHALCOGENIDES
COAL
COMBUSTION PRODUCTS
ENERGY SOURCES
FIELD TESTS
FOSSIL FUELS
FOSSIL-FUEL POWER PLANTS
FUELS
INDUSTRIAL WASTES
MATERIALS
NITROGEN COMPOUNDS
NITROGEN OXIDES
OXIDES
OXYGEN COMPOUNDS
POLLUTION ABATEMENT
POWER PLANTS
SAMPLING
TESTING
THERMAL POWER PLANTS
WASTES