Repair and Strengthening by Use of Superficial Fixed Laminates of Cracked Masonry Walls Sheared Horizontally-Laboratory Tests

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.2963782· OSTI ID:21148928
 [1]; ;  [2]
  1. Department of Structural Engineering, Silesian University of Technology, Akademicka 5, PL-44-100 Gliwice (Poland)
  2. Department of Civil Engineering, Cracow University of Technology, Warszawska 24, PL-31-155 Krakow (Poland)

There are many methods of crack repairing in masonry structures. One of them is repair and strengthening by using of superficial fixed laminates, especially in case of masonry walls with plastering on their both sides. The initial laboratory tests of three different types of strengthening of diagonal cracked masonry wallettes are presented. Tests concerned three clay brick masonry walls subjected to horizontal shearing with two levels of precompression and strengthened by flexible polymer injection, superficial glass fixed by polymer fibre laminate plates and using of CRFP strips stiff fixed to the wall surface by polymer and stiff resin epoxy fixing are presented and discussed.

OSTI ID:
21148928
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 1020; ISSN APCPCS; ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Strengthening of Old Masonry Walls for out-of-Plane Seismic Loading with a CFRP Reinforced Render
Journal Article · Wed Aug 15 00:00:00 EDT 2018 · Experimental Techniques · OSTI ID:22771096

The performance of brick and concrete masonry walls with bonded headers
Conference · Thu Jul 01 00:00:00 EDT 1999 · OSTI ID:20000685

Vibration testing of an epoxy-repaired reinforced concrete test structure
Technical Report · Mon Feb 28 23:00:00 EST 1983 · OSTI ID:6346726