skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: New beam-charge interlock system for radiation safety at the KEKB injector linac

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2839583· OSTI ID:21103865
; ; ;  [1]
  1. Accelerator Laboratory, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)

A new beam-charge interlock system is under development for radiation safety and machine protection at the KEKB injector linac. A hardware-based interlock system is required instead of the present software-based interlock system in order to boost its reliability. This system restricts the integrated amount of beam charges delivered to four different storage rings. The beam charges are measured using wall-current monitors and detection electronics at six locations along the linac. The detection electronics independently transmits a beam-abort request through a twisted hardwire cable directly to the safety control system of the linac, when the integrated amount of beam charges exceeds a certain threshold level prescribed for each location. We describe the characteristics and performance of the new beam-charge interlock system along with the details of the experimental tests.

OSTI ID:
21103865
Journal Information:
Review of Scientific Instruments, Vol. 79, Issue 2; Other Information: DOI: 10.1063/1.2839583; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English