Beam-position monitor system for the KEKB injector linac
Journal Article
·
· AIP Conference Proceedings
- KEK High Energy Accelerator Research Organization 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)
About 90 stripline-type beam position monitors (BPMs) have been newly installed in the KEKB injector linac. These monitors easily reinforce handling beam orbits and measuring the charge of single-bunch electrons and positrons which are injected to the KEKB rings. The design value of the beam position resolution is expected to be less than 0.1 mm. A new data-acquisition (DAQ) system has been developed in order to control these monitors in real time. The hardware and software of 18 front-end computers were tuned for the linac commissioning. This report describes the hardware and software system, the monitor calibration, and preliminary beam test results.
- OSTI ID:
- 21202382
- Journal Information:
- AIP Conference Proceedings, Vol. 451, Issue 1; Conference: 8. beam instrumentation workshop, Stanford, CA (United States), 4-7 May 1998; Other Information: DOI: 10.1063/1.57050; (c) 1998 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Development of beam position detection electronics for the KEKB injector linac
Development of a stripline-type position monitor for the KEK electron/positron linac
New beam-charge interlock system for radiation safety at the KEKB injector linac
Journal Article
·
Wed Jan 01 00:00:00 EST 1997
· AIP Conference Proceedings
·
OSTI ID:21202382
Development of a stripline-type position monitor for the KEK electron/positron linac
Journal Article
·
Mon Oct 10 00:00:00 EDT 1994
· AIP Conference Proceedings
·
OSTI ID:21202382
+1 more
New beam-charge interlock system for radiation safety at the KEKB injector linac
Journal Article
·
Fri Feb 15 00:00:00 EST 2008
· Review of Scientific Instruments
·
OSTI ID:21202382
+1 more