Angiographic Guidewire with Measuring Markers: Design and Clinical Experience

Journal Article · · Cardiovascular and Interventional Radiology
; ; ; ; ; ; ; ;  [1];  [2]
  1. Aichi Medical University, Department of Radiology (Japan)
  2. Nagoya University School of Health Science, Department of Radiological Technology (Japan)

Purpose. We have developed an angiographic guidewire with measuring markers to determine accurately how far a guidewire is inserted within a catheter. We investigated whether use of this guidewire reduces the risk of vascular injury and the fluoroscopic time during guidewire manipulations. Methods. Four markers were put on the surface of the guidewire at 80, 100, 110, and 120 cm from the tip. The actual lengths of 54 catheters from seven manufacturers were measured and compared with the nominal lengths. Sixty consecutive patients who underwent angiography were randomized into two groups: in one group guidewires with surface markers were used (marker group) and in the other group, conventional guidewires (control group). For each guidewire insertion, the fluoroscopic time before the guidewire was pushed forward into the vessel lumen was recorded. The number of occasions on which unintentionally the guidewire had already been pushed out of the catheter at the start of fluoroscopy was also evaluated. Results. The actual lengths of all catheters were greater than the nominal lengths by 1.0-11.0 cm. Mean fluoroscopic time for each guidewire insertion was 3.3 sec in the marker group and 5.7 sec in the control group (p < 0.05). Guidewires were unintentionally pushed out of the catheters without fluoroscopy three times (3.6%), in each case in the control group. Conclusion. The guidewire with measuring markers is effective for enhancing safety and in reducing fluoroscopic radiation during angiographic procedures. It is recommended that operators be aware that actual lengths of catheters may vary significantly from the nominal lengths listed; they should be aware of this with any guidewire, but particularly with the angiographic measuring guidewire.

OSTI ID:
21091091
Journal Information:
Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 6 Vol. 29; ISSN 0174-1551; ISSN CAIRDG
Country of Publication:
United States
Language:
English

Similar Records

A Comparative Study of CT Fluoroscopy Combined with Fluoroscopy Versus Fluoroscopy Alone for Percutaneous Transhepatic Biliary Drainage
Journal Article · Sun Jul 15 00:00:00 EDT 2001 · Cardiovascular and Interventional Radiology · OSTI ID:21083519

The Outback Catheter: A New Device for True Lumen Re-entry After Dissection During Recanalization of Arterial Occlusions
Journal Article · Wed Jan 14 23:00:00 EST 2004 · Cardiovascular and Interventional Radiology · OSTI ID:21088319

Histologic Comparison of Vibrating Guidewire with Conventional Guidewire Technique in an Experimental Coronary In Vivo Model
Journal Article · Mon Sep 15 00:00:00 EDT 2003 · Cardiovascular and Interventional Radiology · OSTI ID:21088355