Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Dilatation of Stent-Grafts by Luminal Pressures: Experimental Evaluation of Polytetrafluoroethylene (PTFE) and Woven Polyester Grafts

Journal Article · · Cardiovascular and Interventional Radiology
DOI:https://doi.org/10.1007/S002700000388· OSTI ID:21083539
; ; ; ; ;  [1]
  1. Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550 (Japan)
Purpose: To evaluate the effect on dilatation of three types of covering materials used for endovascular stent-grafts.Methods: Stent-grafts with three types of covering material [0.1-mm polytetrafluoroethylene (PTFE), 0.2-mm PTFE, and 0.15-mm woven polyester] were placed in a fluid circuit. For the pulsatile pressure test, the luminal pressure of 190/130 mmHg was loaded up to 300,000 pulses. For the static pressure test, the luminal pressure was increased from 50 to 300 mmHg at 50-mmHg increments. The percent of dilatation of each stent-graft was compared.Results: The 0.1-mm PTFE stent-graft was significantly more dilated than the 0.2-mm PTFE and the 0.15-mm woven polyester stent-graft (p < 0.005) in both examinations. There was no significant difference between the 0.2-mm PTFE and the 0.15-mm woven polyester stent-grafts. The dilatation of the 0.1-mm PTFE stent-graft was irreversible.Conclusion: The 0.15-mm woven polyester and the 0.2-mm PTFE stent-grafts may be preferable to the 0.1-mm PTFE stent-graft with regard to dilatation and deformity.
OSTI ID:
21083539
Journal Information:
Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 2 Vol. 24; ISSN 0174-1551; ISSN CAIRDG
Country of Publication:
United States
Language:
English

Similar Records

Primary Implantation of Polyester-Covered Stent-Grafts for Transjugular Intrahepatic Portosystemic Stent Shunts (TIPSS): A Pilot Study
Journal Article · Thu Jul 15 00:00:00 EDT 1999 · Cardiovascular and Interventional Radiology · OSTI ID:21080289

Abdominal Aortic Aneurysm with a Dilated Common Iliac Artery: Treatment Using a Handmade Bifurcated Stent-Graft with a Wide Iliac Limb End
Journal Article · Fri Nov 14 23:00:00 EST 2003 · Cardiovascular and Interventional Radiology · OSTI ID:21088332

Percutaneous Endoluminal Stent-Graft Repair of an Old Traumatic Femoral Arteriovenous Fistula
Journal Article · Thu Mar 14 23:00:00 EST 1996 · Cardiovascular and Interventional Radiology · OSTI ID:21080544