Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Clinical Results of Cerebral Protection with a Filter Device During Stent Implantation of the Carotid Artery

Journal Article · · Cardiovascular and Interventional Radiology
; ; ; ; ; ;  [1]
  1. Department of Radiology, Staedtische Kliniken Dortmund, Beurhausstrasse 40, D-44139 Dortmund (Germany)

Purpose: To assess the technical feasibility and the clinical results of cerebral protection with the Angioguard emboli-capture guidewire system during carotid artery stenting (CAS) for high-grade stenoses.Methods: In 20 patients 20 stenoses of the internal carotid artery were treated with stent implantation. In all patients diffusion-weighted (DW) magnetic resonance imaging (MRI) of the brain was performed before and 24 hr after the procedure.Results: The filter device was effectively employed during all steps of the procedure in 16 of 20 patients, in two only postdilation could be protected, and in two no protection was possible. After three of the 20 procedures new ipsilateral cerebral lesions were visualized by DW-MRI. No new permanent neurologic deficits occurred.Conclusion: Cerebral protection with the filter device is technically feasible in most cases. DW-MRI demonstrated new cerebral lesions indicating the occurrence of cerebral microemboli during the protected procedures. Further investigations are necessary to determine whether the use of the cerebral protection device will improve the results of CAS.

OSTI ID:
21083513
Journal Information:
Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 4 Vol. 24; ISSN 0174-1551; ISSN CAIRDG
Country of Publication:
United States
Language:
English

Similar Records

Extracranial Carotid Artery Stenting in Surgically High-Risk Patients Using the Carotid Wallstent Endoprosthesis:Midterm Clinical and Ultrasound Follow-Up Results
Journal Article · Fri Aug 15 00:00:00 EDT 2003 · Cardiovascular and Interventional Radiology · OSTI ID:21088369

Exclusion of Atherosclerotic Plaque from the Circulation Using Stent-Grafts: Alternative to Carotid Stenting with a Protection Device?
Journal Article · Sat Sep 15 00:00:00 EDT 2007 · Cardiovascular and Interventional Radiology · OSTI ID:21090833

Complications and Follow-up after Unprotected Carotid Artery Stenting
Journal Article · Tue Aug 15 00:00:00 EDT 2006 · Cardiovascular and Interventional Radiology · OSTI ID:21091171