Study on Ferroelectric Thick Film Insulator Sleeve On Plasma Focus

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.2159357· OSTI ID:20729253
; ; ; ;  [1]
  1. Comision Chilena de Energia Nuclear, Casilla 188-D, Santiago (Chile)
The effect of ferroelectric lead germanate Pb5Ge3O11 (PGO) thick film in the alumina insulator sleeve of the 400 Joule Mather-type plasma focus device, PF-400J is studied. The breakdown phase along the insulator is fundamental for the formation of a homogeneous and symmetric current sheath, that is essential for a good plasma pinching, high neutron yield and X-ray emissions. For over several hundreds of electrical discharges, the films show good mechanical and electric performance. From the beginning the operating system is highly reproducible, shot to shot, with a clear definition of the plasma pinch on the axis of discharge. The grade of influence of the electron emission from the ferroelectric is experimentally studied.
OSTI ID:
20729253
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 808; ISSN APCPCS; ISSN 0094-243X
Country of Publication:
United States
Language:
English