Radiotherapy dose calculations in the presence of hip prostheses

Journal Article · · Medical Dosimetry
The high density and atomic number of hip prostheses for patients undergoing pelvic radiotherapy challenge our ability to accurately calculate dose. A new clinical dose calculation algorithm, Monte Carlo, will allow accurate calculation of the radiation transport both within and beyond hip prostheses. The aim of this research was to investigate, for both phantom and patient geometries, the capability of various dose calculation algorithms to yield accurate treatment plans. Dose distributions in phantom and patient geometries with high atomic number prostheses were calculated using Monte Carlo, superposition, pencil beam, and no-heterogeneity correction algorithms. The phantom dose distributions were analyzed by depth dose and dose profile curves. The patient dose distributions were analyzed by isodose curves, dose-volume histograms (DVHs) and tumor control probability/normal tissue complication probability (TCP/NTCP) calculations. Monte Carlo calculations predicted the dose enhancement and reduction at the proximal and distal prosthesis interfaces respectively, whereas superposition and pencil beam calculations did not. However, further from the prosthesis, the differences between the dose calculation algorithms diminished. Treatment plans calculated with superposition showed similar isodose curves, DVHs, and TCP/NTCP as the Monte Carlo plans, except in the bladder, where Monte Carlo predicted a slightly lower dose. Treatment plans calculated with either the pencil beam method or with no heterogeneity correction differed significantly from the Monte Carlo plans.
OSTI ID:
20655446
Journal Information:
Medical Dosimetry, Journal Name: Medical Dosimetry Journal Issue: 2 Vol. 28; ISSN 0958-3947; ISSN MEDOEJ
Country of Publication:
United States
Language:
English

Similar Records

Experimental and Monte Carlo evaluation of Eclipse treatment planning system for effects on dose distribution of the hip prostheses
Journal Article · Tue Oct 01 00:00:00 EDT 2013 · Medical Dosimetry · OSTI ID:22262832

Hip prostheses during pelvic irradiation: effects and corrections
Journal Article · Wed Jun 01 00:00:00 EDT 1988 · Int. J. Radiat. Oncol., Biol. Phys.; (United States) · OSTI ID:6908493

Prostatic thermoluminescent dosimeter analysis in a patient treated with 18 MV X rays through a prosthetic hip
Journal Article · Thu Jan 14 23:00:00 EST 1993 · International Journal of Radiation Oncology, Biology and Physics; (United States) · OSTI ID:6613860