Simplified Numerical Analysis of ECT Probe - Eddy Current Benchmark Problem 3
Journal Article
·
· AIP Conference Proceedings
- Electrical Engineering Faculty, Technical University of Szczecin, ul. Sikorskiego 37, 70-313 Szczecin (Poland)
In this paper a third eddy current benchmark problem is considered. The objective of the benchmark is to determine optimal operating frequency and size of the pancake coil designated for testing tubes made of Inconel. It can be achieved by maximization of the change in impedance of the coil due to a flaw. Approximation functions of the probe (coil) characteristic were developed and used in order to reduce number of required calculations. It results in significant speed up of the optimization process. An optimal testing frequency and size of the probe were achieved as a final result of the calculation.
- OSTI ID:
- 20655364
- Journal Information:
- AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 760; ISSN APCPCS; ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Eddy-current probe characterization
Micro Eddy Current Testing by micro magnetic sensor array
Eddy-current inspection for steam-generator-tubing program. Quarterly progress report for period ending March 31, 1983. [PWR]
Technical Report
·
Mon Oct 01 00:00:00 EDT 1990
·
OSTI ID:6530182
Micro Eddy Current Testing by micro magnetic sensor array
Journal Article
·
Sat Dec 31 23:00:00 EST 1994
· IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States)
·
OSTI ID:6801458
Eddy-current inspection for steam-generator-tubing program. Quarterly progress report for period ending March 31, 1983. [PWR]
Technical Report
·
Mon Aug 01 00:00:00 EDT 1983
·
OSTI ID:5956303