Micro Eddy Current Testing by micro magnetic sensor array

Journal Article · · IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States)
DOI:https://doi.org/10.1109/20.364584· OSTI ID:6801458
; ;  [1]; ;  [2];  [3]
  1. Univ. of Tokyo, Ibaraki (Japan). Nuclear Engineering Research Lab.
  2. Nuclear Fuel Industries, Ltd., Osaka (Japan)
  3. Sumitomo Precision Co. Ltd., Hyogo (Japan)

A micro Eddy Current Testing (ECT) system for planar thin specimens made of INCONEL 600 with flaws was proposed and developed. A micro ECT probe used here consists of a conventional pancake-type coil as an exciting coil and a micro magnetic sensor array as a set of pickup coils. Magnetic field perturbation due to a flaw was measured with high spatial resolution and signal-to-noise (S/N) ratio. The measured signals from the array were compared with numerical results obtained by a three-dimensional A-[phi] code. It was confirmed that the Micro ECT system has the potential to evaluate the length and depth of a flaw with better accuracy than that of a conventional pancake-type ECT in the stream generator tubings in a pressurized water nuclear reactor.

OSTI ID:
6801458
Journal Information:
IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States), Journal Name: IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States) Vol. 31:1Pt2; ISSN IEMGAQ; ISSN 0018-9464
Country of Publication:
United States
Language:
English