Measurement of Inter-Strand Contact Resistance in Epoxy Impregnated Nb3Sn Rutherford Cables
Journal Article
·
· AIP Conference Proceedings
- Fermi National Accelerator Laboratory, Batavia, IL, 60510 (United States)
An apparatus for the measurement, under transverse pressure, of the inter-strand contact resistance in epoxy-impregnated Nb3Sn Rutherford cables has been recently assembled at Fermilab. Procedures have been developed to instrument and measure samples extracted from Nb3Sn coils. Samples were extracted from coils fabricated with the Wind-and-React and the React-and-Wind technology, both presently under development at Fermilab. A ceramic binder is used to improve the insulation and to simplify the fabrication of coils using the Wind-and-React technology. Synthetic oil is used to prevent sintering during the heat treatment of coils to be wound after reaction. In order to evaluate the effects of the ceramic binder and of the synthetic oil on the inter-strand resistance, measurements of samples extracted from coils were compared with measurements of cable stacks with varying characteristics. In this paper we describe the apparatus, the sample preparation, the measurement procedure, and the results of the first series of tests.
- OSTI ID:
- 20653233
- Journal Information:
- AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 711; ISSN APCPCS; ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measurement of inter-strand contact resistance in epoxy impregnated Nb3Sn Rutherford cables
Fabrication of Nb3Sn Shell-Type Coils with Pre-Preg Ceramic Insulation
Design Modifications, Fabrication and Test of HFDB-03 Racetrack Magnet Wound with Pre-Reacted Nb3Sn Rutherford Cable
Conference
·
Tue Oct 07 00:00:00 EDT 2003
·
OSTI ID:816043
Fabrication of Nb3Sn Shell-Type Coils with Pre-Preg Ceramic Insulation
Journal Article
·
Mon Jun 28 00:00:00 EDT 2004
· AIP Conference Proceedings
·
OSTI ID:20653226
Design Modifications, Fabrication and Test of HFDB-03 Racetrack Magnet Wound with Pre-Reacted Nb3Sn Rutherford Cable
Journal Article
·
Wed Jun 23 00:00:00 EDT 2004
· AIP Conference Proceedings
·
OSTI ID:20653186