Present Status of BL40B2 and BL40XU at SPring-8 (Beamlines for Small Angle X-ray Scattering)
Journal Article
·
· AIP Conference Proceedings
- SPring-8/JASRI, Mikazuki, Sayo, Hyogo, 679-5198 (Japan)
BL40B2 and BL40XU were built at SPring-8 in 1999. They are now open for public users and many kinds of small angle x-ray scattering experiments are carried out using these beamlines. We report the present status of these two beamlines. Also some examples of experimental results that were obtained at these beamlines are shown. BL40B2 is for recording small-angle x-ray scattering from non-crystalline biological materials. The light source is a bending magnet and the white x-rays generated by are monochromatized using a double crystal monochromator and focused by a 1-m-long rhodium-coated bent-cylinder mirror. The photon flux is 1x1011 photons/sec at 12.4 keV. The tunable energy range is 7 keV {approx} 18 keV. As a detector, an imaging plate area detector (RIGAKU R-AXIS IV++) is installed. Two fixed-length vacuum paths allow camera lengths of 400 mm and 1000 mm. This beamline is suitable for static measurements with high accuracy and high resolution. The aim of BL40XU is to provide very high flux of x-rays for various experiments. On this concept, BL40XU was designed to use the fundamental undulator radiation as a quasi-monochromatic x-ray beam so that the use of the crystal monochromator was eliminated. The x-ray source of BL40XU is a helical undulator and its flux is estimated to be 1x10 and 15 photons/sec at 12.4 keV. The x-ray is focused horizontally and vertically by bending two water-cooled focusing mirrors. So far, various time-resolved diffraction and scattering experiments on biomaterials and polymers have been carried out.
- OSTI ID:
- 20652947
- Journal Information:
- AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 705; ISSN APCPCS; ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
X-ray Beamlines On A Superconducting Wavelength Shifter
Design And Performance Of An X-ray Undulator Beamline PF-AR-NW2
The high-flux beamline at the ESRF
Journal Article
·
Wed May 12 00:00:00 EDT 2004
· AIP Conference Proceedings
·
OSTI ID:20652968
Design And Performance Of An X-ray Undulator Beamline PF-AR-NW2
Journal Article
·
Wed May 12 00:00:00 EDT 2004
· AIP Conference Proceedings
·
OSTI ID:20652925
The high-flux beamline at the ESRF
Journal Article
·
Tue Dec 31 23:00:00 EST 1991
· Review of Scientific Instruments; (United States)
·
OSTI ID:5569549
Related Subjects
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
ACCURACY
BIOLOGICAL MATERIALS
KEV RANGE 01-10
KEV RANGE 10-100
LIGHT SOURCES
MAGNETS
MIRRORS
MONOCHROMATIC RADIATION
MONOCHROMATORS
PHOTONS
POLYMERS
PROTEINS
RHODIUM
SMALL ANGLE SCATTERING
SPRING-8 STORAGE RING
SYNCHROTRON RADIATION
TIME RESOLUTION
X-RAY DIFFRACTION
X-RAY SOURCES
X-RAY SPECTRA
ACCURACY
BIOLOGICAL MATERIALS
KEV RANGE 01-10
KEV RANGE 10-100
LIGHT SOURCES
MAGNETS
MIRRORS
MONOCHROMATIC RADIATION
MONOCHROMATORS
PHOTONS
POLYMERS
PROTEINS
RHODIUM
SMALL ANGLE SCATTERING
SPRING-8 STORAGE RING
SYNCHROTRON RADIATION
TIME RESOLUTION
X-RAY DIFFRACTION
X-RAY SOURCES
X-RAY SPECTRA