Title: Galvanic protection of an offshore loading pipeline in the Baltic Sea

Journal Article · · Materials Performance
OSTI ID:20076111

A two-component galvanic anode cathodic protection system was designed, procured, and installed on an offshore loading pipeline. An estimate of the initial coating damage (presumed undetected and buried) was factored into the coating efficiency data for design. The contingency factor for current spread of 1.5 times the bracelet spacing was verified during detailed design and confirmed during construction. An initial potential survey of the onshore portion prior to its activation indicated that current propagation provided by the offshore system extended all the way to Kilometer Post 0.00, near the isolating flange at the terminal.

Research Organization:
Fluor Daniel, Inc. (US)
OSTI ID:
20076111
Journal Information:
Materials Performance, Vol. 39, Issue 5; Other Information: PBD: May 2000; ISSN 0094-1492
Country of Publication:
United States
Language:
English

Similar Records

Cathodic protection of offshore pipelines
Journal Article · Sun Feb 01 00:00:00 EST 1981 · Pipeline Gas J.; (United States) · OSTI ID:20076111

Offshore cathodic protection design, inspection, and computer modeling: Innovations from the 1980s
Journal Article · Wed Dec 01 00:00:00 EST 1993 · Materials Performance; (United States) · OSTI ID:20076111

Cathodic protection with reduced wave load features for an offshore steel jacket