Placement of ventilation air intakes for improved IAQ
Conference
·
OSTI ID:20002283
ASHRAE Research Project 806, Design Criteria for Building Ventilation Inlets, reviews existing knowledge of the placement of ventilation air louvers, produces a design guide, and suggests additional research, all with the intention of improving indoor air quality in commercial and institutional buildings. Decisions about intake and exhaust placements made early in the architectural and HVAC system design processes will impact occupants over the life of a building. Such placement decisions, therefore, require proper consideration. There is little guidance currently available to designers, but research efforts in this area are expanding. Previous research efforts and standards relating to ventilation air intake placement are described in this paper. However, more extensive coverage and a lengthy bibliography are provided in the project's ``Literature Report''. In ``A Designer' Guide to Placement of Ventilation Air Intake Louvers'' for the project, the phenomena, standards, and design experiences that affect the placement of intake air louvers are reviewed using less technical text, many graphics, and example calculations. More research is needed on ventilation intake placement for common commercial HVAC systems with rooftop, through-the-wall, and at-grade louvers. Most existing knowledge is derived from the many studies on industrial stack exhaust-gas reentrainment and not common HVAC geometries. The findings of such future research and a summary of this project's Designer's Guide need to be included in future revisions of ASHRAE Handbook chapters.
- Research Organization:
- Univ. of Kansas, Lawrence, KS (US)
- OSTI ID:
- 20002283
- Report Number(s):
- CONF-990102--; ISSN 0001-2505
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measuring Outdoor Air Intake Rates into Existing Building
Measuring OutdoorAir Intake Rates Using Electronic Velocity Sensors at Louvers and Downstream of Airflow Straighteners
Technologies for measuring flow rates of outdoor air into HVACsystems: Some causes and suggested cures for measurement errors
Technical Report
·
Thu Apr 16 00:00:00 EDT 2009
·
OSTI ID:994011
Measuring OutdoorAir Intake Rates Using Electronic Velocity Sensors at Louvers and Downstream of Airflow Straighteners
Technical Report
·
Wed Oct 01 00:00:00 EDT 2008
·
OSTI ID:944427
Technologies for measuring flow rates of outdoor air into HVACsystems: Some causes and suggested cures for measurement errors
Journal Article
·
Sun Oct 31 23:00:00 EST 2004
· ASHRAE Transactions
·
OSTI ID:881724