EBRII cask characterization measurements
This report describes the measurements performed to provide the radionuclide content and verify the stated mass of special nuclear material (SNM) in Experimental Breeder Reactor EBRII casks stored in Trench 1, Burial Ground 4C, 218-WAC 200 West Area. this information is needed to characterize the curie content of each cask and the total curies in the storage area. Gamma assay techniques typically employed for nondestructive assay (NDA) were used to determine the gamma-emitting isotopes in each cask, which were fission and activation products from the spent fuel. Passive neutron counting was selected to verify the stated plutonium content because the fission and activation products masked any gamma emissions from plutonium. The fast neutrons emitted by plutonium are highly penetrating and easily detected through several inches of shielding. A slab neutron detector containing five {sup 3}He proportional counters was used to determine the neutron emission rates and estimate the mass of plutonium present. The measurements followed the methods and procedures routinely used for nuclear waste assay and safeguard measurements. The measured neutron yields confirmed the declared plutonium content for the fuel elements, with the exception of several casks that contained recycled plutonium or americium target material. In these casks, the {sup 244}Cm content masked the neutron emissions from any plutonium. For these casks, the plutonium content was estimated by correlation with the {sup 244}Cm neutron emissions.
- Research Organization:
- Pacific Northwest Lab., Richland, WA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 197852
- Report Number(s):
- PNNL--10910; ON: DE96004607
- Country of Publication:
- United States
- Language:
- English
Similar Records
Determination of the radioactive material and plutonium holdup in ducts and piping in the 324 Building
Verification of Special Nuclear Material (SNM) using Active Well Coincidence Counter (AWCC) and a High Purity Germanium (HPGe) Detector
Determination of the radioactive material and plutonium holdup in ducts and piping in the 327 Building
Technical Report
·
Sun Dec 31 19:00:00 EST 1995
·
OSTI ID:197851
Verification of Special Nuclear Material (SNM) using Active Well Coincidence Counter (AWCC) and a High Purity Germanium (HPGe) Detector
Conference
·
Wed Jul 01 00:00:00 EDT 2020
·
OSTI ID:23030300
Determination of the radioactive material and plutonium holdup in ducts and piping in the 327 Building
Technical Report
·
Thu Aug 31 20:00:00 EDT 1995
·
OSTI ID:113871