This is the fifteenth quarterly report describing the activities performed under Contract No. DE-AC21-94MC31160. The analyses of Hot Gas Stream Cleanup (HGCU) ashes and descriptions of filter performance studied under this contract are designed to address problems with filter operation that are apparently linked to characteristics of the collected ash. Task 1 is designed to generate a data bank of the key characteristics of ashes collected from operating advanced particle filters (APFs) and to relate these ash properties to the operation and performance of these filters and their components. APF operations have also been limited by the strength and durability of the ceramic materials that have served as barrier filters for the capture of entrained HGCU ashes. Task 2 concerns testing and failure analyses of ceramic filter elements currently used in operating APFs and the characterization and evaluation of new ceramic materials. Task 1 research activities during the past quarter included characterizations of samples collected during a site visit on May 18 to the Department of Energy / Southern Company Services Power Systems Development Facility (PSDF) and a particulate sample collected in the Westinghouse filter at Sierra Pacific Power Company's Piñon Pine Power Project. Analysis of this Piñon Pine sample is ongoing: however, this report contains the results of analyses completed to date. Significant accomplishments were achieved on the HGCU data bank during this reporting quarter. The data bank was prepared for presentation at the Advanced Coal-Based Power and Environmental Systems 98 Conference scheduled for July, 1998. Task 2 work during the past quarter consisted of testing two Dupont PRD-66C candle filters, one McDermott ceramic composite candle filter, one Blasch 4-270 candle filter, and one Specific Surface cordierite candle filter. Tensile and thermal expansion testing is complete and the rest of the testing is in progress. Also, some 20-inch long Dupont PRD-66C, McDermott ceramic composite, and Westinghouse Techniweave candle filters have been received for testing after their exposure to the gasification environment. One as-manufactured and one exposed element was received of each material and specimens are currently being machined from these candles.

Research Organization:
Federal Energy Technology Center, Morgantown, WV, and Pittsburgh, PA
Sponsoring Organization:
USDOE
DOE Contract Number:
AC21-94MC31160
OSTI ID:
1968
Report Number(s):
DE-AC21-94MC31160--28; ON: DE00001968
Country of Publication:
United States
Language:
English

Similar Records

Particulate hot gas stream cleanup technical issues. Quarterly report, January 1--March 31, 1998
Technical Report · Sat Aug 01 00:00:00 EDT 1998 · OSTI ID:674614

ADVANCED SECOND GENERATION CERAMIC CANDLE FILTERS
Technical Report · Wed Jan 30 23:00:00 EST 2002 · OSTI ID:829652

PARTICULATE HOT GAS STREAM CLEANUP TECHNICAL ISSUES
Technical Report · Thu Feb 25 23:00:00 EST 1999 · OSTI ID:9067