Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

M-Star® Modeling of SME Mixing with Three Impeller Blades

Technical Report ·
DOI:https://doi.org/10.2172/1922497· OSTI ID:1922497
 [1];  [1]
  1. Savannah River Nuclear Solutions (SRNS), Aiken, SC (United States); Savannah River National Laboratory (SRNL), Aiken, SC (United States)
Before a sample of the Slurry Mix Evaporator (SME) can be taken, the SME product sampling procedure requires that the agitator power be stable between 20 and 30 kW for at least one hour. The SME transfer to Melter Feed Tank (MFT) procedure also requires the SME agitator power be stabilized between 20 and 30 kW prior to transfer. These requirements are specified to ensure samples are homogeneous, as discussed in the Waste Form Qualification Report. During SME Batch 804, the agitator power dropped to 19 kW and struggled to achieve and maintain 20 kW. It was later discovered that the cause of the power drop was due to one of the bottom blades of the agitator breaking off. Both the sample and the transfer occurred without the power stabilizing between 20 and 30 kW. Therefore, the quality of SME Batch 804 is indeterminate, and homogeneity was questionable. To evaluate mixing in the SME with a broken agitator containing only three blades (90 degrees apart with space for a missing blade) on the bottom impeller, the Savannah River National Laboratory (SRNL) was requested to perform computer simulations of impeller mixing in the SME using M-Star® software. The simulations will be used to determine if SME Batch 804 was well mixed and satisfies homogeneity requirements.
Research Organization:
Savannah River Site (SRS), Aiken, SC (United States); Savannah River National Laboratory (SRNL), Aiken, SC (United States)
Sponsoring Organization:
USDOE Office of Environmental Management (EM)
DOE Contract Number:
89303321CEM000080
OSTI ID:
1922497
Report Number(s):
SRNL-STI-2022-00492
Country of Publication:
United States
Language:
English

Similar Records

M-Star® Software Test and Verification for Impeller Mixing in a Tank
Technical Report · Tue Nov 01 00:00:00 EDT 2022 · OSTI ID:1908981

Uniformity of material in the SME and MFT
Technical Report · Fri May 29 00:00:00 EDT 1992 · OSTI ID:6981798

Uniformity of material in the SME and MFT