Assessment of Low-Cost Minisplit Heat Pump Connection System
- National Renewable Energy Laboratory (NREL), Golden, CO (United States)
This project was funded by SCE's Emerging Technologies Program, and evaluates the feasibility of a connection system that can pave the path to accelerated, cost-effective adoption of high-efficiency Minisplit Heat Pump (MSHP) systems. This report details the characterization of this connection system and a heat pump enabled with this technology in a laboratory setting, and assesses the energy and cost impact applicable to residential buildings in SCE service territory. The energy and economic analysis leverages NREL's ResStockTM modeling approach based on the EnergyPlus® hourly simulation platform. The connection system can be incorporated into existing MSHP architectures. This reduces installation time from 10 to 20 man hours to approximately one hour or less, dramatically lowering total installation costs without adversely impacting heat pump performance. This report characterizes the connection system's leakage performance while connected and disconnected, as well as leakage over several connection/disconnection cycles, commensurate with manufacturer specifications for the individual components. The connector was incorporated into an off-the-shelf MSHP. Performance was compared to an identical unmodified heat pump. The connector had no impact on performance. Large-scale hourly energy simulations were performed for 22,574 homes across 15 counties in SCE service territory. The analysis was performed using baseline assumptions about the penetrations of window air conditioners (~18%) and six upgrade scenarios for these air conditioners. All scenarios assumed 100% adoption of the Connector-Supported Heat Pump (CSHP) in place of window air conditioners: MSHPs at Seasonal Energy Efficiency Ratio (SEER) 17, 25, and 33, and CSHPs at SEER 17, 25, and 33. Results show the increased adoption of high-efficiency heat pumps can result in up to 29% air conditioning energy savings for homes with window air conditioners.
- Research Organization:
- National Renewable Energy Laboratory (NREL), Golden, CO (United States)
- Sponsoring Organization:
- Southern California Edison (SCE), Emerging Technologies Program; USDOE
- DOE Contract Number:
- AC36-08GO28308
- OSTI ID:
- 1922100
- Report Number(s):
- NREL/TP-5500-77737; ET17SCE7070; MainId:30652; UUID:1f68050a-8f6d-412a-9ad6-2bfd5b03fdad; MainAdminID:68547
- Country of Publication:
- United States
- Language:
- English
Similar Records
An Integrated Control Method for Supplemental Minisplit Heat Pumps in Existing Homes
Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps
Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps
Technical Report
·
Wed Sep 01 00:00:00 EDT 2021
·
OSTI ID:1814927
Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps
Technical Report
·
Mon Sep 09 00:00:00 EDT 2024
·
OSTI ID:2441256
Consumer life-cycle cost impacts of energy-efficiency standards for residential-type central air conditioners and heat pumps
Conference
·
Wed Oct 10 00:00:00 EDT 2001
·
OSTI ID:799569