Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Assessment of Low-Cost Minisplit Heat Pump Connection System

Technical Report ·
DOI:https://doi.org/10.2172/1922100· OSTI ID:1922100
 [1];  [1];  [1]
  1. National Renewable Energy Laboratory (NREL), Golden, CO (United States)
This project was funded by SCE's Emerging Technologies Program, and evaluates the feasibility of a connection system that can pave the path to accelerated, cost-effective adoption of high-efficiency Minisplit Heat Pump (MSHP) systems. This report details the characterization of this connection system and a heat pump enabled with this technology in a laboratory setting, and assesses the energy and cost impact applicable to residential buildings in SCE service territory. The energy and economic analysis leverages NREL's ResStockTM modeling approach based on the EnergyPlus® hourly simulation platform. The connection system can be incorporated into existing MSHP architectures. This reduces installation time from 10 to 20 man hours to approximately one hour or less, dramatically lowering total installation costs without adversely impacting heat pump performance. This report characterizes the connection system's leakage performance while connected and disconnected, as well as leakage over several connection/disconnection cycles, commensurate with manufacturer specifications for the individual components. The connector was incorporated into an off-the-shelf MSHP. Performance was compared to an identical unmodified heat pump. The connector had no impact on performance. Large-scale hourly energy simulations were performed for 22,574 homes across 15 counties in SCE service territory. The analysis was performed using baseline assumptions about the penetrations of window air conditioners (~18%) and six upgrade scenarios for these air conditioners. All scenarios assumed 100% adoption of the Connector-Supported Heat Pump (CSHP) in place of window air conditioners: MSHPs at Seasonal Energy Efficiency Ratio (SEER) 17, 25, and 33, and CSHPs at SEER 17, 25, and 33. Results show the increased adoption of high-efficiency heat pumps can result in up to 29% air conditioning energy savings for homes with window air conditioners.
Research Organization:
National Renewable Energy Laboratory (NREL), Golden, CO (United States)
Sponsoring Organization:
Southern California Edison (SCE), Emerging Technologies Program; USDOE
DOE Contract Number:
AC36-08GO28308
OSTI ID:
1922100
Report Number(s):
NREL/TP-5500-77737; ET17SCE7070; MainId:30652; UUID:1f68050a-8f6d-412a-9ad6-2bfd5b03fdad; MainAdminID:68547
Country of Publication:
United States
Language:
English