An Integrated Control Method for Supplemental Minisplit Heat Pumps in Existing Homes

Technical Report ·
DOI:https://doi.org/10.2172/1814927· OSTI ID:1814927
 [1];  [2];  [2];  [2]
  1. Univ. of Central Florida, Orlando, FL (United States); FSEC Energy Research Center, Cocoa, FL (United States); FSEC Energy Research Center
  2. Univ. of Central Florida, Orlando, FL (United States); FSEC Energy Research Center, Cocoa, FL (United States)
The FSEC Energy Research Center(FSEC) at the University of Central Florida has investigated low-cost space-conditioning upgrade solutions for existing homes since 2014. The retrofits involve installing a modest capacity, centrally located, high efficiency, ductless, minisplit heat pump (MSHP) for use in conjunction with the home’s existing central space conditioning system (CSCS). This type of retrofit targets homes with older but not obsolete CSCSs that have not reached end of life, and presents a more cost-effective option to achieve space conditioning energy savings than outright CSCS replacement. This report describes results from investigating the energy savings potential, given adherence to comfort management, if the control of the MSHP and CSCS were integrated.
Research Organization:
Univ. of Central Florida, Orlando, FL (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office
DOE Contract Number:
EE0008183
OSTI ID:
1814927
Report Number(s):
DOE/GO--102021-5492
Country of Publication:
United States
Language:
English

Similar Records

Maximizing the Use of Ductless Mini-Splits in Homes with Existing Central or Zonal Heating and Cooling Equipment
Technical Report · Sun May 31 00:00:00 EDT 2020 · OSTI ID:1635162

Ductless Mini-Split Heat Pump Comfort Evaluation
Technical Report · Thu Feb 28 23:00:00 EST 2013 · OSTI ID:1219961

Phased Retrofits in Existing Homes in Florida Phase II: Shallow Plus Retrofits
Technical Report · Wed Nov 30 23:00:00 EST 2016 · OSTI ID:1358048