Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Smart soft contact lenses for continuous 24-hour monitoring of intraocular pressure in glaucoma care

Journal Article · · Nature Communications

Continuous monitoring of intraocular pressure, particularly during sleep, remains a grand challenge in glaucoma care. Here we introduce a class of smart soft contact lenses, enabling the continuous 24-hour monitoring of intraocular pressure, even during sleep. Uniquely, the smart soft contact lenses are built upon various commercial brands of soft contact lenses without altering their intrinsic properties such as lens power, biocompatibility, softness, transparency, wettability, oxygen transmissibility, and overnight wearability. We show that the smart soft contact lenses can seamlessly fit across different corneal curvatures and thicknesses in human eyes and therefore accurately measure absolute intraocular pressure under ambulatory conditions. We perform a comprehensive set of in vivo evaluations in rabbit, dog, and human eyes from normal to hypertension to confirm the superior measurement accuracy, within-subject repeatability, and user comfort of the smart soft contact lenses beyond current wearable ocular tonometers. We envision that the smart soft contact lenses will be effective in glaucoma care.

Research Organization:
Purdue Univ., West Lafayette, IN (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Basic Energy Sciences (BES). Materials Sciences & Engineering Division
Grant/Contract Number:
SC0021967
OSTI ID:
1903256
Journal Information:
Nature Communications, Journal Name: Nature Communications Journal Issue: 1 Vol. 13; ISSN 2041-1723
Publisher:
Nature Publishing GroupCopyright Statement
Country of Publication:
United States
Language:
English

References (51)

The Pathophysiology and Treatment of Glaucoma journal May 2014
Measured Changes in Limbal Strain During Simulated Sleep in Face Down Position Using an Instrumented Contact Lens in Healthy Adults and Adults With Glaucoma journal April 2016
Measurement of Intraocular Pressure by Patients With Glaucoma journal October 2017
An Ultrasensitive Contact Lens Sensor Based On Self‐Assembly Graphene For Continuous Intraocular Pressure Monitoring journal May 2021
Contact Lens Sensors in Ocular Diagnostics journal November 2014
Printing Flexible and Hybrid Electronics for Human Skin and Eye‐Interfaced Health Monitoring Systems journal July 2019
Recent Advances in Smart Contact Lenses journal November 2019
The pressure difference between eye and brain changes with posture journal July 2016
Latanoprost for open-angle glaucoma (UKGTS): a randomised, multicentre, placebo-controlled trial journal April 2015
Glaucoma journal November 2017
Soft contact lens polymers: an evolution journal December 2001
Tissue and cellular biomechanics during corneal wound injury and repair journal August 2017
Effect of Different Head Positions in Lateral Decubitus Posture on Intraocular Pressure in Treated Patients With Open-Angle Glaucoma journal November 2015
What We Have Learned From the Ocular Hypertension Treatment Study journal May 2018
Comparison of patient-reported visual outcome methods to quantify the perceptual effects of defocus journal October 2012
Giant papillary conjunctivitis: A review journal July 2020
Integrated contact lens sensor system based on multifunctional ultrathin MoS2 transistors journal March 2021
Effects of Different Sleeping Postures on Intraocular Pressure and Ocular Perfusion Pressure in Healthy Young Subjects journal August 2013
Normal-Tension Glaucoma Has Normal Intracranial Pressure journal March 2018
24-h monitoring devices and nyctohemeral rhythms of intraocular pressure journal November 2016
Discovery and clinical translation of novel glaucoma biomarkers journal January 2021
Gas-Permeable, Irritation-Free, Transparent Hydrogel Contact Lens Devices with Metal-Coated Nanofiber Mesh for Eye Interfacing journal June 2019
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics journal April 2017
High resolution non-invasive intraocular pressure monitoring by use of graphene woven fabrics on contact lens journal August 2019
What is the best way to measure intraocular pressure (IOP) in a virtual clinic? journal April 2020
Systems genetics identifies a role for Cacna2d1 regulation in elevated intraocular pressure and glaucoma susceptibility journal November 2017
Soft transparent graphene contact lens electrodes for conformal full-cornea recording of electroretinogram journal June 2018
All-printed stretchable corneal sensor on soft contact lenses for noninvasive and painless ocular electrodiagnosis journal March 2021
A mussel-inspired film for adhesion to wet buccal tissue and efficient buccal drug delivery journal March 2021
Rapid custom prototyping of soft poroelastic biosensor for simultaneous epicardial recording and imaging journal June 2021
A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure journal May 2021
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays journal July 2021
Materials for flexible bioelectronic systems as chronic neural interfaces journal May 2020
Skin-integrated wireless haptic interfaces for virtual and augmented reality journal November 2019
Generalized parity–time symmetry condition for enhanced sensor telemetry journal May 2018
Three-dimensional integrated stretchable electronics journal August 2018
Three-dimensional curvy electronics created using conformal additive stamp printing journal September 2019
Wireless, passive strain sensor in a doughnut-shaped contact lens for continuous non-invasive self-monitoring of intraocular pressure journal January 2020
Application of graphene nanowalls in an intraocular pressure sensor journal January 2020
In vivo measurement of trabecular meshwork stiffness in a corticosteroid-induced ocular hypertensive mouse model journal January 2019
Can the SENSIMED Triggerfish® lens data be used as an accurate measure of intraocular pressure? journal April 2017
Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays journal January 2018
Printing of wirelessly rechargeable solid-state supercapacitors for soft, smart contact lenses with continuous operations journal December 2019
Wireless smart contact lens for diabetic diagnosis and therapy journal April 2020
Smart, soft contact lens for wireless immunosensing of cortisol journal July 2020
Smart contact lens and transparent heat patch for remote monitoring and therapy of chronic ocular surface inflammation using mobiles journal April 2021
Eye problems in contact lens wearers journal November 2019
Animal Models of Glaucoma journal January 2012
Historical Data: Histopathology Lesions Observed in the Eyes of Control Rabbits in Topical Ocular Administration and Contact Lens Studies journal October 2018
Ocular rigidity journal June 2010
The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives journal May 2017

Similar Records

Controlled five-year follow-up study of laser trabeculoplasty as primary therapy for open-angle glaucoma
Journal Article · Thu Oct 15 00:00:00 EDT 1987 · Am. J. Ophthalmol.; (United States) · OSTI ID:5628690

Treatment of absolute painful glaucoma with dynamic arcs using novalis shaped beam radiosurgery
Journal Article · Tue Nov 14 23:00:00 EST 2006 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20850194

Molecular genetics of the glaucomas: Mapping of the first five {open_quotes}GLC{close_quotes} loci
Journal Article · Fri Jan 31 23:00:00 EST 1997 · American Journal of Human Genetics · OSTI ID:518505