A fiber-coupled dispersion interferometer for density measurements of pulsed power transmission line electron sheaths on Sandia’s Z machine

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/5.0101687· OSTI ID:1896820

A fiber-coupled Dispersion Interferometer (DI) is being developed to measure the electron density of plasmas formed in power flow regions, such as magnetically insulated transmission lines, on Sandia National Laboratories (SNL’s) Z machine [D. B. Sinars et al., Phys. Plasmas 27, 070501 (2020)]. The diagnostic operates using a fiber-coupled 1550 nm CW laser with frequency-doubling to 775 nm. The DI is expected to be capable of line-average density measurements between ∼1013 and 1019 cm−2. Initial testing has been performed on a well-characterized RF lab plasma [A. G. Lynn et al., Rev. Sci. Instrum. 80, 103501 (2009)] at the University of New Mexico to quantify the density resolution lower limits of the DI. Initial testing of the DI has demonstrated line-average electron density measurements within 9% of results acquired via a 94 GHz mm wave interferometer for line densities of ∼1 × 1014 cm−2, despite significant differences in probe beam geometries. The instrument will next be utilized for measurements on a ∼1 MA-scale pulsed power driver {MYKONOS [N. Bennett et al., Phys. Rev. Accel. Beams 22, 120401 (2019)] at SNL} before finally being deployed on SNL’s Z machine. The close electrode spacing (mm scale) on Z requires probe beam sizes of ∼1 mm, which can only be obtained with visible or near infrared optical systems, as opposed to longer wavelength mm wave systems that would normally be chosen for this range of density.

Sponsoring Organization:
USDOE
OSTI ID:
1896820
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 11 Vol. 93; ISSN 0034-6748
Publisher:
American Institute of PhysicsCopyright Statement
Country of Publication:
United States
Language:
English

References (7)

A sensitive dispersion interferometer with high temporal resolution for electron density measurements journal July 2000
Fiber optic two-color vibration compensated interferometer for plasma density measurements journal October 2006
The HelCat dual-source plasma device journal October 2009
Review of pulsed power-driven high energy density physics research on Z at Sandia journal July 2020
Current transport and loss mechanisms in the Z accelerator journal December 2019
EUV spectroscopy of plasmas created in the final anode-cathode gap of the Z-Machine high-current pulsed generator (SNL) journal November 2008
Versatile second-harmonic interferometer with high temporal resolution and high sensitivity based on a continuous-wave Nd:YAG laser journal January 2007

Similar Records

Current Loss in 0.1 - 100 Terawatt Vacuum Transmission Lines: Experiments and Simulations
Technical Report · Sat Sep 01 00:00:00 EDT 2018 · OSTI ID:1474261

Single-shot electron bunch length measurements using a spatial electro-optical autocorrelation interferometer
Journal Article · Fri Oct 15 00:00:00 EDT 2010 · Review of Scientific Instruments · OSTI ID:22058635

Related Subjects