High power density soft x-ray GaAs photodiodes with tailored spectral response
Journal Article
·
· Semiconductor Science and Technology
- Stony Brook University, NY (United States)
- Brookhaven National Lab. (BNL), Upton, NY (United States). National Synchrotron Light Source II (NSLS-II)
GaAs photodiode arrays have been designed for non-destructive monitoring of x-ray beam position in soft coherent beamline front ends in synchrotron light sources. A shallow p-on-n junction was employed to reduce the device photocurrent density to optimize the operation with beam power densities up to 20 W mm-2, mainly coming from hard x-rays. With this approach, the photocurrent is primarily defined by the excess carriers generated by low-energy x-ray photons absorbed near the detector surface. The p–n junction structures were grown by molecular beam epitaxy and processed into 64-element linear photodiode arrays. The devices were characterized first in the visible range with a high-power Ar-ion laser and then tested in the soft and hard x-ray regions up to 10 keV at two beamlines of the National Synchrotron Light Source II. The responsivity was measured to be 0.16 A W-1 at 0.7 keV and 0.05 A W-1 at 6 keV in agreement with modeling. At higher x-ray energies the measured responsivity was lower than predicted in the framework of the carrier diffusion model; a possible explanation is discussed.
- Research Organization:
- Brookhaven National Laboratory (BNL), Upton, NY (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), Basic Energy Sciences (BES)
- Grant/Contract Number:
- SC0012704
- OSTI ID:
- 1889176
- Report Number(s):
- BNL-223438-2022-JAAM
- Journal Information:
- Semiconductor Science and Technology, Journal Name: Semiconductor Science and Technology Journal Issue: 8 Vol. 37; ISSN 0268-1242
- Publisher:
- IOP PublishingCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Similar Records
Responsivity of Diamond X-ray Photodiodes Calibrated at NSLS
Responsivity of Diamond X-ray Photodiodes Calibrated at NSLS
X-ray response of AlGaAs/GaAs radiation-hardened double-heterostructure photodiode compared to Si:p-i-n photodiodes
Conference
·
Sun Sep 27 00:00:00 EDT 2009
·
OSTI ID:970615
Responsivity of Diamond X-ray Photodiodes Calibrated at NSLS
Journal Article
·
Wed Jun 23 00:00:00 EDT 2010
· AIP Conference Proceedings
·
OSTI ID:21410368
X-ray response of AlGaAs/GaAs radiation-hardened double-heterostructure photodiode compared to Si:p-i-n photodiodes
Journal Article
·
Mon Aug 01 00:00:00 EDT 1988
· Rev. Sci. Instrum.; (United States)
·
OSTI ID:7123487