X-ray Source Characteristics from July 2020 SGEMP Experiments at the National Ignition Facility
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
- Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
This report details the measured x-ray characteristics radiating from laser targets on 7 shots at Lawrence Livermore National Laboratory's National Ignition Facility performed June 30 - July 2, 2020. Generally, the x-ray sources were designed to serve as meaningful drivers of a variety of Radiation Effects Sciences response experiments. Specifically, on these 7 shots, the measured x-ray output characteristics and the response experiments serve as a useful data set for validating performance and informing further development of Sandia National Laboratories' EMPIRE code. We present x-ray measurements and analyses relevant to simulating the System-Generated Electro Magnetic Pulse experiments that also occurred on these shots (described elsewhere). Sufficient detail is provided so that a motivated, but novice, x-ray source user could produce some of these analysis results from raw data on similar x-ray shots.
- Research Organization:
- Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA)
- DOE Contract Number:
- NA0003525
- OSTI ID:
- 1841956
- Report Number(s):
- SAND2021-12034; 701557
- Country of Publication:
- United States
- Language:
- English
Similar Records
TMS XTRRA experiments on NIF
Thermo-Mechanical Shock, X-Ray Transport and Radiation Response Analysis Experiments on NIF
Crystal response measurement of the x-ray transmission crystals used by the Imaging Spectroscopy Snout at the National Ignition Facility
Technical Report
·
Wed Aug 12 00:00:00 EDT 2020
·
OSTI ID:1650443
Thermo-Mechanical Shock, X-Ray Transport and Radiation Response Analysis Experiments on NIF
Technical Report
·
Wed Nov 25 23:00:00 EST 2020
·
OSTI ID:1727271
Crystal response measurement of the x-ray transmission crystals used by the Imaging Spectroscopy Snout at the National Ignition Facility
Journal Article
·
Thu Nov 03 20:00:00 EDT 2022
· Review of Scientific Instruments
·
OSTI ID:1897293