This paper summarizes the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements using the ORIGEN data analysis module for 23 boiling water reactor spent fuel assemblies that were performed in Finland under an international collaboration on spent fuel safeguards verification methods. PNAR is part of the proposed integrated nondestructive system to be used for safeguards verifications at the planned Finnish encapsulation facility. Besides measuring passive neutron and gamma emission rates from an assembly like a Fork detector, PNAR also measures the PNAR ratio, which is expected to correlate with the fissile content in the assembly. The emission rates and PNAR ratio can be used to verify the operator declarations and the fissile content of an assembly, respectively. The analysis was performed using the ORIGEN Data Analysis Module, which was originally developed for predicting Fork detector neutron and gamma signals for spent fuel measurements and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the IAEA. The Module includes the ORIGEN burnup analysis code and integrates detector response functions pre-generated using MCNP to predict detector signals in several seconds per assembly. In this study, new response functions specific to PNAR measurements were generated for ORIGEN Module. The study also analyzes impacts of using detailed fuel design and operation information vs. standard safeguards information on results calculated by ORIGEN Module. Using detailed information reduced the standard deviation of relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. This paper describes how ORIGEN Module calculates the expected PNAR neutron and gamma signals and PNAR ratio and how they compare with corresponding measured values.
- Research Organization:
- Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-00OR22725
- OSTI ID:
- 1817423
- Country of Publication:
- United States
- Language:
- English
Similar Records
Analysis with the ORIGEN Module of PNAR Spent Fuel Measurements for Nuclear Safeguards Applications
Simulated Performance of the Integrated PNAR and SINRD Detector Designed for Spent Fuel Measurements at the Fugen Reactor in Japan
Validation of ORIGEN for VVER-440 Spent Fuel with Application to Fork Detector Safeguards Measurements
Technical Report
·
Mon Nov 30 23:00:00 EST 2020
·
OSTI ID:1760108
Simulated Performance of the Integrated PNAR and SINRD Detector Designed for Spent Fuel Measurements at the Fugen Reactor in Japan
Conference
·
Fri Jul 13 00:00:00 EDT 2012
·
OSTI ID:1046503
Validation of ORIGEN for VVER-440 Spent Fuel with Application to Fork Detector Safeguards Measurements
Journal Article
·
Sun May 31 20:00:00 EDT 2020
· ESARDA Bulletin
·
OSTI ID:1649471