Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Validation of ORIGEN for VVER-440 Spent Fuel with Application to Fork Detector Safeguards Measurements

Journal Article · · ESARDA Bulletin
OSTI ID:1649471
The US Department of Energy National Nuclear Security Administration and the European Atomic Energy Community (Euratom) are collaborating with the Radiation and Nuclear Safety Authority in Finland to assess spent fuel verification methods for potential application to measurements at the planned spent fuel encapsulation plant and geological repository prior to final disposal in Finland. The fork detector (FDET) used to measure the neutron and gamma radiation from a given spent fuel assembly is an existing technology widely used by the International Atomic Energy Agency (IAEA) and Euratom for the safeguards verification of spent fuel operator declaration. Recently, an FDET data analysis software, referred to as the ORIGEN module, was developed and incorporated into the IAEA/Euratom Integrated Review and Analysis Program. This module uses the ORIGEN burnup code to calculate the nuclide concentrations and the neutron and gamma source terms in the spent fuel based on operator declarations. Then, to predict the expected FDET signals for a given fuel assembly, the module combines the source terms calculated by ORIGEN with FDET response functions that were pre-generated using MCNP models. The inspector can compare the calculated signals to the measured values in real time to identify possible anomalies in fuel assembly’s operator declaration, integrity, or measurement. In this work, the capability of the ORIGEN module was extended from application to typical light water reactor fuels to use for VVER-440 assembly types. The accuracy of ORIGEN for this type of fuel assembly calculations was assessed by comparing calculated nuclide concentrations against destructive assay measurements for VVER-440 spent fuel. The performance of the ORIGEN module for FDET safeguards verification in routine inspections was assessed using FDET measurement data for 13 spent VVER-440 assemblies that were measured at the Loviisa Nuclear Power Plant in Finland, by comparing the calculated signals to the measured quantities. The results show that the calculated FDET neutron and gamma detector signals are generally within 12% of the measurements except for one assembly. Thus, these results are applicable to future safeguards verification in the planned Finland encapsulation plant, such as for passive neutron albedo reactivity safeguards measurements.
Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE
Grant/Contract Number:
AC05-00OR22725
OSTI ID:
1649471
Journal Information:
ESARDA Bulletin, Journal Name: ESARDA Bulletin Journal Issue: 1 Vol. 60; ISSN 0392-3029
Publisher:
European Safeguards Research & Development AssociationCopyright Statement
Country of Publication:
United States
Language:
English

Similar Records

Analysis of PNAR Spent Fuel Safeguards Measurements using the ORIGEN Data Analysis Module
Conference · Sun Aug 01 00:00:00 EDT 2021 · OSTI ID:1817423

Analysis with the ORIGEN Module of PNAR Spent Fuel Measurements for Nuclear Safeguards Applications
Technical Report · Mon Nov 30 23:00:00 EST 2020 · OSTI ID:1760108

Advancing the Fork detector for quantitative spent nuclear fuel verification
Journal Article · Tue Jan 30 19:00:00 EST 2018 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1424458