Conventional invasive diagnostic imaging techniques do not adequately resolve complex Type B and C coronary lesions, which present unique challenges, require personalized treatment and result in worsened patient outcomes. These lesions are often excluded from large-scale non-invasive clinical trials and there does not exist a validated approach to characterize hemodynamic quantities and guide percutaneous intervention for such lesions. This work identifies key biomarkers that differentiate complex Type B and C lesions from simple Type A lesions by introducing and validating a coronary angiography-based computational fluid dynamic (CFD-CA) framework for intracoronary assessment in complex lesions at ultrahigh resolution. Among 14 patients selected in this study, 7 patients with Type B and C lesions were included in the complex lesion group including ostial, bifurcation, serial lesions and lesion where flow was supplied by collateral bed. Simple lesion group included 7 patients with lesions that were discrete, <10mm long and readily accessible. Intracoronary assessment was performed using CFD-CA framework and validated by comparing to clinically measured pressure-based index, such as FFR. Local pressure, endothelial shear stress (ESS) and velocity profiles were derived for all patients. We validates the accuracy of our CFD-CA framework and report excellent agreement with invasive measurements (n=14,R2=0.6,p=0.0013). Ultra-high resolution achieved by the model enable physiological assessment in complex lesions and quantify hemodynamic metrics in all vessels up to 1mm in diameter. Importantly, we demonstrate that in contrast to traditional pressure-based metrics, there is a significant difference in the intracoronary hemodynamic forces, such as ESS, in complex lesions compared to simple lesions at both resting and hyperemic physiological states [n = 14, p=0.03]. Higher ESS was observed in the complex lesion group (7.0±4.7 Pa) than in simple lesion group (4.8±3.6 Pa). Complex coronary lesions have higher ESS compared to simple lesions, such differential hemodynamic evaluation can provide much the needed insight into the increase in adverse outcomes for such patients and has incremental prognostic value over traditional pressure-based indices, such as FFR.
Vardhan, Madhurima, Gounley, John, Chen, S. James, Chi, Eric, Kahn, Andrew M., Leopold, Jane A., & Randles, Amanda (2021). Non-invasive characterization of complex coronary lesions. Scientific Reports, 11(1). https://doi.org/10.1038/s41598-021-86360-6
@article{osti_1779148,
author = {Vardhan, Madhurima and Gounley, John and Chen, S. James and Chi, Eric and Kahn, Andrew M. and Leopold, Jane A. and Randles, Amanda},
title = {Non-invasive characterization of complex coronary lesions},
annote = {Conventional invasive diagnostic imaging techniques do not adequately resolve complex Type B and C coronary lesions, which present unique challenges, require personalized treatment and result in worsened patient outcomes. These lesions are often excluded from large-scale non-invasive clinical trials and there does not exist a validated approach to characterize hemodynamic quantities and guide percutaneous intervention for such lesions. This work identifies key biomarkers that differentiate complex Type B and C lesions from simple Type A lesions by introducing and validating a coronary angiography-based computational fluid dynamic (CFD-CA) framework for intracoronary assessment in complex lesions at ultrahigh resolution. Among 14 patients selected in this study, 7 patients with Type B and C lesions were included in the complex lesion group including ostial, bifurcation, serial lesions and lesion where flow was supplied by collateral bed. Simple lesion group included 7 patients with lesions that were discrete, 2=0.6,p=0.0013). Ultra-high resolution achieved by the model enable physiological assessment in complex lesions and quantify hemodynamic metrics in all vessels up to 1mm in diameter. Importantly, we demonstrate that in contrast to traditional pressure-based metrics, there is a significant difference in the intracoronary hemodynamic forces, such as ESS, in complex lesions compared to simple lesions at both resting and hyperemic physiological states [n = 14, p=0.03]. Higher ESS was observed in the complex lesion group (7.0±4.7 Pa) than in simple lesion group (4.8±3.6 Pa). Complex coronary lesions have higher ESS compared to simple lesions, such differential hemodynamic evaluation can provide much the needed insight into the increase in adverse outcomes for such patients and has incremental prognostic value over traditional pressure-based indices, such as FFR.},
doi = {10.1038/s41598-021-86360-6},
url = {https://www.osti.gov/biblio/1779148},
journal = {Scientific Reports},
issn = {ISSN 2045-2322},
number = {1},
volume = {11},
place = {United States},
publisher = {Nature Publishing Group},
year = {2021},
month = {04}}
Randles, Amanda Peters; Kale, Vivek; Hammond, Jeff
2013 IEEE International Symposium on Parallel & Distributed Processing (IPDPS), 2013 IEEE 27th International Symposium on Parallel and Distributed Processinghttps://doi.org/10.1109/IPDPS.2013.109
Randles, Amanda; Draeger, Erik W.; Oppelstrup, Tomas
SC15: The International Conference for High Performance Computing, Networking, Storage and Analysis, Proceedings of the International Conference for High Performance Computing, Networking, Storage and Analysishttps://doi.org/10.1145/2807591.2807676
PASC '17: Platform for Advanced Scientific Computing Conference, Proceedings of the Platform for Advanced Scientific Computing Conferencehttps://doi.org/10.1145/3093172.3093227